Dell C7008 Specifications

Browse online or download Specifications for Network switches Dell C7008. Dell C7008 Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Installing and Maintaining

Installing and Maintainingthe C7008/C300 System

Page 2

10 | About this Guidewww.dell.com | support.dell.com

Page 3 - Contents

Installing and Maintaining the C300 System 112OverviewThe C7008/C300 is a high performance switch/router. The 10-slot system contains two slots for Ro

Page 4 - 4

12 | Overviewwww.dell.com | support.dell.comC-Series System Installation ProcessThe Dell Networking recommended installation process is described belo

Page 5 - Contents

Installing and Maintaining the C300 System 133Preparing the SiteSite Selection CriteriaBefore beginning the installation process, make sure that the a

Page 6 - 6

14 | Preparing the Sitewww.dell.com | support.dell.comRack MountingWhen you prepare your equipment rack:• Make sure that the rack is bolted to the flo

Page 7 - About this Guide

Preparing the Site | 15Shipping and Storing Components CAUTION: Do not transport a C7008/C300 chassis with the components (line cards, supplies, and

Page 8

16 | Preparing the Sitewww.dell.com | support.dell.com

Page 9 - Related Documents

Installing C7008/C300 Fan Tray | 174Installing C7008/C300 Fan Tray The C7008/C300 chassis contains one field-replaceable fan tray. There are two types

Page 10 - 10

18 | Installing C7008/C300 Fan Traywww.dell.com | support.dell.comTo install the fan tray: NOTE: The fan tray LED will remain lit when the chassis is

Page 11 - Overview

Installing RPMs and Line Cards | 195Installing RPMs and Line CardsThe C-Series System accommodates eight line cards and two RPMs.Route Processor Modul

Page 12 - 12

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indi

Page 13 - Preparing the Site

20 | Installing RPMs and Line Cardswww.dell.com | support.dell.comLine CardsLine cards are hot-swappable. Any line card can be inserted into any line

Page 14 - Requirements

Installing RPMs and Line Cards | 21 NOTE: The fan tray face panel has slot number markings for the RPMs and line cards. Insert the fan tray before the

Page 15 - Preparing the Site

22 | Installing RPMs and Line Cardswww.dell.com | support.dell.com5 Rotate the levers towards the card to seat the backplane connectors and line card

Page 16 - 16

Installing RPMs and Line Cards | 23Figure 5-5. Installing a Line CardFigure 5-6. Installing an RPM Card LeverCard GuideCard LeverCard Guide

Page 17

24 | Installing RPMs and Line Cardswww.dell.com | support.dell.com

Page 18 - Removing the Fan Tray

Installing and Maintaining the C300 System 256RPM CablesConnecting the Console PortThe console port is an asynchronous serial port. If you connect a d

Page 19 - Route Processor Modules

26 | RPM Cableswww.dell.com | support.dell.comAccessing the Console with a DB-9 AdapterYou can connect to the console using a RJ-45 to RJ-45 rollover

Page 20 - Blank Panels

RPM Cables | 27Table 6-3. Pin Assignments Between C7008/C300 Console and DB-25 Adapter C-Series System Console PortRJ-45 to RJ-45 Rollover Cable RJ-4

Page 21 - Step Task

28 | RPM Cableswww.dell.com | support.dell.com

Page 22

Installing AC Power Supplies | 297Installing AC Power SuppliesThe C7008/C300 has eight power supply slots at the front-bottom of the chassis (Figure 7

Page 23 - Card Lever

Contents | 3Contents1 About this GuideInformation Symbols and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Page 24

30 | Installing AC Power Supplieswww.dell.com | support.dell.comFigure 7-1. Power Supply Location

Page 25 - RPM Cables

Installing AC Power Supplies | 31Figure 7-2. AC Power SupplyEach AC power supply has one LED as described in Table 7-1. This LED does not function un

Page 26

32 | Installing AC Power Supplieswww.dell.com | support.dell.comInstalling the AC Power Supply WARNING: Use only the power cord supplied with the pow

Page 27

Installing AC Power Supplies | 33The following tables provide a mapping between the supported PoE/PoE+ ports and the PSUs for a system configuration t

Page 28 - 28

34 | Installing AC Power Supplieswww.dell.com | support.dell.com211 (System Redundancy)3036438(System Redundancy)4 118 785 171 1186 224 1587 278 1988

Page 29 - Installing AC Power Supplies

Installing DC Power Entry Modules | 358Installing DC Power Entry ModulesThe C7008/C300 has eight supply slots at the front-bottom of the chassis (Figu

Page 30

36 | Installing DC Power Entry Moduleswww.dell.com | support.dell.com• Rated for 60A service to allow for a fully loaded C-Series system per NEC in th

Page 31 - RPM is installed

Installing DC Power Entry Modules | 37Step Task (continued)4 Slide the PEM into slot 0 or 7 (see (Figure 8-2). If you are installing redundant PEMs, i

Page 32 - Power Over Ethernet (PoE)

38 | Installing DC Power Entry Moduleswww.dell.com | support.dell.comFigure 8-3. Grounding7 Remove the outer nuts and washers from each of the remain

Page 33

Installing DC Power Entry Modules | 39Status LEDThe status LED indicates the condition of the PEM.Removing a DC PEMThe left chassis PEM slot is labell

Page 34

4 | Contentswww.dell.com | support.dell.com8 Installing DC Power Entry ModulesRecommended Normal Operating Conditions . . . . . . . . . . . . . . . .

Page 35 - Redundancy

40 | Installing DC Power Entry Moduleswww.dell.com | support.dell.com

Page 36 - Installing a DC PEM

Installing and Maintaining the C300 System 419Powering UpBefore you supply power to the chassis, Dell Networking recommends that you re-inspect your e

Page 37

42 | Powering Upwww.dell.com | support.dell.comSupplying WARNING: Never operate the C-Series System without a fan tray. WARNING: The C7008/C300 ope

Page 38 - -48V Connectors

Powering Up | 43 NOTE: Do not press any keys or control sequences at any time during the boot process. Doing so may cause the boot process to terminat

Page 39 - Removing a DC PEM

44 | Powering Upwww.dell.com | support.dell.com

Page 40

Installing and Maintaining the C300 System 4510Removing and Replacing ComponentsThis section provides instructions for removing and replacing the foll

Page 41 - Powering Up

46 | Removing and Replacing Componentswww.dell.com | support.dell.comFigure 10-1. Fan Tray (Left)To remove and replace the fan tray: Removing and Rep

Page 42 - Supplying

Removing and Replacing Components | 47To remove and replace a supply: Removing and Replacing a Line Card WARNING: Do not remove a panel blank unless

Page 43 - ). The console monitor will

48 | Removing and Replacing Componentswww.dell.com | support.dell.comRemoving and Replacing an RPM WARNING: After removing an RPM, place a panel blan

Page 44 - 44

Removing and Replacing Components | 49To remove and replace a C7008/C300 RPM: Step Task 1 Unplug any network interface cables connected to the RPM.2

Page 45

Contents | 5Electromagnetic Compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Product Recycling and Disposal .

Page 46

50 | Removing and Replacing Componentswww.dell.com | support.dell.com

Page 47

Installing the Chassis | 5111Installing the Chassis Safety Considerations NOTE: Use an equipment lift or pallet jack when lifting or moving the chass

Page 48 - Removing and Replacing an RPM

52 | Installing the Chassiswww.dell.com | support.dell.comStep Task1 Install the equipment rack bar. This bar enables you to easily position the chass

Page 49

Installing the Chassis | 534 Insert screws (provided with your rack) through the chassis rack-mounting bracket and into the equipment rack, and tighte

Page 50

54 | Installing the Chassiswww.dell.com | support.dell.com

Page 51 - Installing the Chassis

System Boot | 5512System BootWhen you supply power to the C-Series System, the system performs a series of on self-tests. RPM and line card Status LED

Page 52 - 52

56 | System Bootwww.dell.com | support.dell.comTo configure the chassis from the BOOT_USER prompt, use the following commands:CommandPurpose help or

Page 53 - Figure 11-2

System Boot | 57Refer to the C-Series Dell Networking OS Command Line Reference for BOOT_USER mode commands and commands for run-time modes. show inte

Page 54 - 54

58 | System Bootwww.dell.com | support.dell.com

Page 55 - System Boot

The Compact Flash Card | 5913The Compact Flash Card Each RPM is designed with a slot (slot0:) to accommodate a Compact Flash Card (external compact fl

Page 56

6 | Contentswww.dell.com | support.dell.com

Page 57

60 | The Compact Flash Cardwww.dell.com | support.dell.comTo remove the flash memory card:Formatting the Compact Flash Card New Compact Flash cards mu

Page 58 - 58

Alarms | 61AAlarmsThe C-Series System generates alarms for the following conditions:• fan tray status• supply status• RPMs status• high temperature o

Page 59 - The Compact Flash Card

62 | Alarmswww.dell.com | support.dell.comAC Supplies and AlarmsDuring system boot, if a redundant supply is removed or fails, the Dell Networking gen

Page 60 - 60

Installing and Maintaining the C300 System 63BSystem SpecificationsPhysical DesignChassis Dimensions Table B-1. Chassis DimensionsParameter Specifica

Page 61 - Status LED on

64 | System Specificationswww.dell.com | support.dell.comComponent Dimensions System SpecificationsTable B-2. Component DimensionsComponent Length (i

Page 62 - AC Supplies and Alarms

System Specifications | 65Component Power Requirements NOTE: The listed requirement for the PoE version of line cards excludes the required power fo

Page 63 - System Specifications

66 | System Specificationswww.dell.com | support.dell.com NOTE: Additional components may be available for your system, other than those included in

Page 64 - Component Dimensions

System Specifications | 67Japan: VCCI Compliance for Class A Equipment This is Class A product based on the standard of the Voluntary Control Council

Page 65 - Component Power Requirements

68 | System Specificationswww.dell.com | support.dell.com• EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification Requirements and User’

Page 66 - Agency Compliance

System Specifications | 69Figure B-1. The European WEEE Symbol In accordance with the European WEEE Directive, electrical and electronic equipment (E

Page 67 - • EN 60825-1

About this Guide | 71About this Guide This guide provides site preparation recommendations and instructions for installing the Dell Networking C-Serie

Page 68 - Products

70 | System Specificationswww.dell.com | support.dell.com

Page 69 - The European WEEE Symbol

Contacting Technical Support | 71CContacting Technical Support The iSupport WebsiteiSupport provides a range of documents and tools to assist you with

Page 70 - 70

72 | Contacting Technical Supportwww.dell.com | support.dell.comLocating Serial Numbers• The chassis serial number is below the barcode on the sticker

Page 71 - Contacting Technical Support

Contacting Technical Support | 733 When returning an RMA component, follow the packing and shipping directions in the Return Instructions document tha

Page 72 - Locating Serial Numbers

74 | Contacting Technical Supportwww.dell.com | support.dell.com

Page 74

www.dell.com | support.dell.comPrinted in the U.S.A.

Page 75

8 | About this Guidewww.dell.com | support.dell.com WARNING: Building Supply Notice for AC Supply Use.This product relies on the building's inst

Page 76 - Printed in the U.S.A

About this Guide | 9Related Documents For more information about the C-Series system, refer to the following documents:•Dell Networking OS Command Ref

Comments to this Manuals

No comments