Dell R7910 Owner's Manual Page 89

  • Download
  • Add to my manuals
  • Print
  • Page
    / 142
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 88
CAUTION: To prevent damage to the control panel flex cable, do not to bend the control panel
flex cable after it is inserted into the connector.
1. Use the hooks on the chassis as guides to align the hard-drive backplane.
2. Slide down the hard-drive backplane until the release tabs snap into place.
3. Connect the HHD/SSD data, signal, and power cable to the backplane.
1. Replace the cooling-fan assembly.
2. Replace the cooling shroud.
3. Install the hard drives in their original locations.
4. Follow the procedure listed in After working inside your system .
Control panel assembly
Removing the control panel
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Slide the control panel from the chassis.
CAUTION: Do not use excessive force when removing the control panel as it can damage the
connectors.
2. From inside the system, push the control panel out of the chassis.
3. Remove all the cables connecting the control panel to the chassis.
1. control panel
89