53-1001809-01January 31, 2010 53-1001809-01*53-1001809-01*Blade and Filler PanelReplacement ProcedureSupporting PowerConnect B-DCX4-S Backbone, DCX Ba
10 Blade and Filler Panel Replacement Procedure 53-1001809-01FIGURE 6 FC4-48 Port blade1 Power LED 3 Fibre Channel port2 Status LED 4 Port Status LED2
Blade and Filler Panel Replacement Procedure 11 53-1001809-01FIGURE 7 FC10-6 Port blade1 Power LED 3 Fibre Channel port2 Status LED 4 Port Status LED
12 Blade and Filler Panel Replacement Procedure 53-1001809-01FIGURE 8 FC4-16IP Application blade1 Power LED 3 Fibre Channel port2 Status LED 4 Port St
Blade and Filler Panel Replacement Procedure 13 53-1001809-01FIGURE 9 FR4-18i Application blade1 Power LED 3 Fibre Channel port2 Status LED 4 Port St
14 Blade and Filler Panel Replacement Procedure 53-1001809-01FIGURE 10 FA4-18 Application blade1 Power LED 3 Fibre Channel port2 Status LED 4 Port Sta
Blade and Filler Panel Replacement Procedure 15 53-1001809-01FIGURE 11 FS8-18 Application blade1 Power LED 3 Fibre Channel port2 Status LED 4 Port St
16 Blade and Filler Panel Replacement Procedure 53-1001809-01FIGURE 12 FX8-24 extension blade110 GbE ports 6Blade Power LED2-3 1 GbE ports 7 Blade Sta
Blade and Filler Panel Replacement Procedure 17 53-1001809-01FIGURE 13 FCOE10-24 FCoE bladeRemoval and replacement of a bladeThis section describes h
18 Blade and Filler Panel Replacement Procedure 53-1001809-01For the PowerConnect B-DCX-4S, slots are numbered from 1 through 8, from bottom to top wh
Blade and Filler Panel Replacement Procedure 19 53-1001809-01Figure 16 illustrates how to remove or replace a sample blade with ejectors and slider s
2 Blade and Filler Panel Replacement Procedure 53-1001809-01Notes, Cautions, and WarningsNOTEA NOTE indicates important information that helps you mak
20 Blade and Filler Panel Replacement Procedure 53-1001809-01FIGURE 14 Removing and replacing a blade with ejectors only (FC4-48 shown) in a PowerConn
Blade and Filler Panel Replacement Procedure 21 53-1001809-01FIGURE 15 Port, application, or encryption blade (FC8-48 port blade shown) in a PowerCon
22 Blade and Filler Panel Replacement Procedure 53-1001809-01FIGURE 16 Removing and replacing a blade with ejectors and slider switches (FC4-16 shown)
Blade and Filler Panel Replacement Procedure 23 53-1001809-01ATTENTIONFollow ESD precautions (“ESD precautions”).1. Ensure that all packing material
24 Blade and Filler Panel Replacement Procedure 53-1001809-01FIGURE 17 Removing and replacing a blade filler panel for a PowerConnect B-DCX (PowerConn
Blade and Filler Panel Replacement Procedure 25 53-1001809-01FIGURE 18 Removing and replacing a blade filler panel for a PowerConnect B-DCX4-SReplaci
26 Blade and Filler Panel Replacement Procedure 53-1001809-01
Blade and Filler Panel Replacement Procedure 3 53-1001809-01In this guide•Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Blade and Filler Panel Replacement Procedure 53-1001809-01Attention noticesAn attention notice indicates the possibility of damage to a program, dev
Blade and Filler Panel Replacement Procedure 5 53-1001809-01FIGURE 1 FC8-16 Port blade1 Power LED 3 Fibre Channel port2 Status LED 4 Port Status LED3
6 Blade and Filler Panel Replacement Procedure 53-1001809-01FIGURE 2 FC8-32 Port blade1 Power LED 3 Fibre Channel port2 Status LED 4 Port Status LED13
Blade and Filler Panel Replacement Procedure 7 53-1001809-01FIGURE 3 FC8-48 Port blade1 Power LED 3 Fibre Channel port2 Status LED 4 Port Status LED3
8 Blade and Filler Panel Replacement Procedure 53-1001809-01FIGURE 4 FC4-16 Port blade1 Power LED 4 Port Speed LED2 Status LED 5 Port Status LED3 Fibr
Blade and Filler Panel Replacement Procedure 9 53-1001809-01FIGURE 5 FC4-32 Port blade1 Power LED 5 Port Status LED (left port)2 Status LED 6 Port Sp
Comments to this Manuals