28 Event Message Reference
1304 Redundancy regained
Redundancy unit:
<Redundancy
location in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state was:
<State>
Information A redundancy sensor in the specified system
detected that a “lost” redundancy device has
been reconnected or replaced; full redundancy
is in effect. The redundancy unit location,
chassis location, previous redundancy state,
and the number of devices required for full
redundancy are provided.
1305 Redundancy degraded
Redundancy unit:
<Redundancy
location in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state was:
<State>
Warning A redundancy sensor in the specified system
detected that one of the components of the
redundancy unit has failed but the unit is
still redundant. The redundancy unit
location, chassis location, previous redundancy
state, and the number of devices required
for full redundancy are provided.
1306 Redundancy lost
Redundancy unit:
<Redundancy
location in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state was:
<State>
Warnin g or
Error
(depending
on the
number of
units that are
functional)
A redundancy sensor in the specified system
detected that one of the components in the
redundant unit has been disconnected, has
failed, or is not present. The redundancy
unit location, chassis location, previous
redundancy state, and the number of devices
required for full redundancy are provided.
Table 2-7. Redundancy Unit Messages (continued)
Event ID Description Severity Cause