Upgrading to Dell/EMC CX4 Series Storage Systems
Applied Technology 10
MirrorView
When MirrorView/Synchronous or MirrorView/Asynchronous is installed, the port used by MirrorView will not
change. The logical port numbering will be carried through the conversion. This eliminates the need for a zoning
change to connect the MirrorView ports. Table 4 lists the iSCSI and FC MirrorView ports in use with previous
models.
Table 4. Port usage and MV ports by model
Array
Port numbers and type per SP
0
1
2
3
4
5
CX300
FC
FC
CX300i
iSCSI
iSCSI
CX3-10c
iSCSI
iSCSI/MV
FC
FC/MV
CX3-20
FC
FC/MV
CX3-20c
iSCSI
iSCSI
iSCSI
iSCSI/MV
FC
FC/MV
CX3-20f
FC
FC/MV
FC
FC
FC
FC
CX500
FC
FC/MV
CX500i
iSCSI
iSCSI
CX3-40
FC
FC/MV
CX3-40c
iSCSI
iSCSI
iSCSI
iSCSI/MV
FC
FC/MV
CX3-40f
FC
FC/MV
FC
FC
CX700
FC
FC
FC
FC/MV
CX3-80
FC
FC
FC
FC/MV
Legend:
FC = Fibre Channel port, iSCSI = iSCSI port, /MV = port used by MirrorView
All mirrors need to be administratively fractured and all SAN Copy sessions stopped before the upgrade. SnapView
snapshot sessions and clone groups do not need to be altered. All persistent replication sessions and checkpoints will
be preserved through the upgrade. This means, for example, that a SAN Copy incremental session does not require
another initial synchronization following the upgrade.
If upgrading from a CX300 with SAN Copy/E installed, the SAN Copy/E enabler must be removed before the
upgrade or incompatibility messages will be displayed after the upgrade. All CX4 series platforms support full SAN
Copy.
Upgrading with Celerra
®
Gateways Attached
Although this is unlikely to be the case, Dell/EMC array upgrades are supported when attached to Dell/EMC N500G
(Celerra) NAS gateways. This is the only Celerra NAS gateway that Dell has resold up to this time. Upgrades are
supported for gateway systems only and not integrated NAS systems. Be sure to indicate that a NAS gateway is
attached when generating the conversion procedure in the CPG.
The N500G uses standard Dell/EMC LUNs for both control data and user data. Celerra control LUNs are usually
placed on the first five Dell/EMC drives, which may conflict with the reserved space expansion required when
upgrading from a CX or CX3 series to a CX4 series. The CAP2 conversion readiness check report will report which
LUNs need to be moved and Celerra CLI tools may be used to determine which of the LUNs identified for
migration are NAS LUNs.