Page view 2
A Principled Technologies test report 3
Improving database performance with Dell Fluid Cache for SAN
Figure 1: Dell Fluid Cache for
SAN communication.
Three nodes are required when running Dell Fluid Cache for SAN software in
order to provide resiliency and replicate data in the cache pool. Two nodes must have at
least one PCIe SSD each, and the network is a high-speed RDMA network. The RDMA
network handles the cluster caching communication between the nodes. Creation of the
Fluid Cache cluster on the SAN is accomplished using the Dell Compellent Enterprise
Manager software through automatic cache server discovery through the Fluid Cache
management network.
OUR TEST CONFIGURATION
We first tested our database workload with two servers running Oracle 12c
database Standard Edition in an Oracle RAC configuration (Baseline solution) running on
SUSE Linux Enterprise 11 Service Pack 3. In this configuration, only Oracle RAC database
software ran on the two nodes. Figure 2 depicts our test setup for the baseline solution.