Dell POWERVAULT MD3600I User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
5
Insert the second (new or replacement) controller module in the empty slot
(slot 1) of the enclosure.
For insertion procedures and slot labeling, see the
Hardware Owner’s Manual
for your MD storage array.
6
Connect the expansion enclosures (if present) to the controller module you
added in slot 1.
NOTE: Wait for the enclosure status LED to turn blue before proceeding to the
next step.
7
In
MD Storage Manager
, double-click the storage array you are upgrading.
The
Array Management Window
(AMW) is displayed.
8
If not using DHCP or default IPv6 address, you may be required to manually
specify the IP configuration. To manually specify the IP configuration:
a
Select the
Setup
tab.
b
Select
Configure Ethernet Management Ports
and from
Ethernet port
,
select
RAID Controller
Module 1, Port 0
.
c
Select
Specify configuration
.
d
Modify the configuration to match
RAID Controller Module 0
.
e
Click
OK
.
9
In the
Enterprise Management Window
, select the
Setup
tab, and click
Add
Storage Arrays
.
10
In the
Select Addition Method
window, select
Manual
and click
OK
.
The
Add New Storage Array – Manual
window is displayed.
11
Select
Out-of-band management
.
12
In the
RAID Controller Module (DNS/Network name, IPv4 address or IPv6
address)
fields, enter the IP addresses of both the RAID controllers installed in
the storage enclosure.
13
Click
Add
.
14
A message prompts you if you want to add another storage array, click
No
.
NOTE: The Devices tab in the Enterprise Management Window displays both
management port IP addresses for the newly upgraded duplex storage array.
15
Adjust the virtual disk caching options:
ModeUpgrade.fm Page 11 Thursday, March 29, 2012 1:43 PM
Page view 2
1 2 3 4 5 6

Comments to this Manuals

No comments