Threshold Settings and Converting Formulas
The following table lists the system sensor’s threshold settings and formulas
for converting the sensor readings.
Table 1-62. Threshold Settings and Converting Formulas
Sensor
Number
Sensor Name The Converting Formula
Upper non-
recoverable
Upper
critical
Upper
non-
critical
Lower non-
recoverable
Lower
critical
Lower
non-
critical
Voltage
05h 12 V Standby Actual_Reading (Volts) = ((Raw_Data x 65) + 60) x 0.001
D4 CA C1 9C A6 AF
06h 5 V Actual_Reading (Volts) = ((Raw_Data x276) + 100) x
0.0001
D0 C7 BE 9A A3 AC
07h 5 V Standby Actual_Reading (Volts) = ((Raw_Data x 277) + 80) x
0.0001
D0 C7 BE 9A A3 AC
08h 3.3 V Actual_Reading (Volts) = ((Raw_Data x 199) + 70) x
0.0001
BF B7 AE 8D 95 9E
09h 3.3 V Standby Actual_Reading (Volts) = ((Raw_Data x 197) + 100) x
0.0001
C1 B9 B0 8F 97 A0