Dell PowerEdge C410x User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 122
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
9
NOM Information (Mexico Only)
The following information is provided on the device described in this document in compliance with the
requirements of the official Mexican standards (NOM):
Importer: Dell Inc. de México, S.A. de C.V
Paseo de la Reforma 2620-11° Piso
Col. Lomas Altas
11950 México, D.F.
Model Number: B02S
Supply voltage: 200-240 VCA
Frequency: 50/60 Hz
Current Consumption 9.6 A (for each power inlet)
Technical Specifications
System Specifications
1. Chassis
Form Factor
3U
Size (LxWxH)
L = 750mm
W = 440mm
H = 130.5mm
PCI Card Access
(F/R/I)
Total of 16 PCI Express individual modules per chassis.
Servicing one module does not affect other modules in the chassis.
Front of Chassis = 10 Modules
Back of Chassis = 6 Modules
Fans
Eight 92 mm x 38 mm
N+1 Redundancy
Hot Swappable Fans
BMC notification of system fan failure
Serviceability
Removal or insertion of PCI Module does not require any change in operation of the
chassis or other PCI Modules installed within the chassis.
LED Indicators
Power LED, System Status LED, ID LED, Fan LED