Dell PowerVault 57F User's Guide Page 225

  • Download
  • Add to my manuals
  • Print
  • Page
    / 246
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 224
Script Commands 225
faultDiagnostics {testDevices=[all | controller=(0
| 1) |
emms=[
trayID1
(left | right), ...
trayIDn
(left |
right)] |
physicalDisks=[
trayID1
,
slotID1
, ... ,
trayIDn
,
slotIDn
]] |
dataPattern=(fixed | pseudoRandom) |
patternNumber=[(
0xhexadecimal
|
integerLiteral
)] |
maxErrorCount=
integer
| testIterations=
integer
|
timeout=
timeInterval
}
Parameters
Parameter Description
controller The identifier letter of the RAID controller module that
you want to test. Valid RAID controller module identifier
values are 0 or 1, where 0 is the RAID controller module on
the left, and 1 is the RAID controller module on the right
when viewed from the rear of the enclosure.
testDevices The identifiers of the devices (RAID controller modules,
EMMs, or physical disks) that you want to test. You can
specify all or enter the specific identifiers for the devices
that you want to diagnose.
dataPattern The method of repeatability that you want to test.
patternNumber The hexadecimal data pattern you want to use to run the
test.
This number can be any hexadecimal number between
0000 to FFFF.
maxErrorCount The number of errors that you want to accept before
terminating the test.
testIterations The number of times that you want to repeat the test.
timeout The length of time in minutes that you want to run the test.