Dell PowerEdge Select Network AdaptersThe Freedom to Choose
14
I2C interface
I2C clock and data signals are connected to the TFRU. The Field Replaceable Unit (FRU) part is
specific to Dell programs and comes preprogrammed with the base FRU code, greatly simplifying
manufacturing of the device. It also includes a temperature sensor.
PowerEdge platforms that support Select Network Adapters
The Blade Select Network Adapter is offered on the PowerEdge M620 blade server.
The Rack Select Network Adapter is offered on the following PowerEdge platforms:
R620
R720
R720xd
System integration
Features for Select Network Adapter system integration include Device Disable, WoL, and iDRAC
integration.
Device Disable
The Select Network Adapter supports disabling the LAN controller(s) by putting the device(s) into the
lowest power state. The Select Network Adapter supports an enable/disable mechanism exposed
through the BIOS F2 setup or Dell USC tool. This allows a card level disable where all ports are on or
off.
Wake on LAN
The NDC connects to the system chipset PCI Power Management Event pin to generate power
management events in Wake on LAN (WOL) implementations.
When the system is operating in Vaux with WoL enabled, the device driver uses link auto-negotiation
to advertise the lowest-supported speed in attempt to negotiate the lowest speed possible to
conserve power. The 10GBASE-T device will not link up at 10Gbps when operating in Vaux due to the
large Vaux power requirement.
Wake on LAN is supported on only one port in a server at any given time.
iDRAC integration
The NDC supports a Shared LOM Port for iDRAC communication via any port over the NC-SI sideband
interface.