Technical Specifications
The aggregator is an I/O module and installed with the Dell PowerEdge FX2 server chassis for
communication.
NOTE: Replace the battery only with same or equivalent type. Dispose of the batteries according to
the manufacturer's instructions.
Table 4. Environmental Parameters
Parameter Specifications
Operating temperature
20 °C/h (36 °F/h)
Storage temperature -40° to 158°F (-40° to 70°C)
Relative humidity (Storage)
5% to 95% RH with 33 °C (91 °F) maximum dew
point. Atmosphere must be non-condensing at all
times.
Maximum thermal output
475 BTU/hr
Maximum altitude
Operating
Storage
3048 m (10,000 ft)
12000m (39,370ft)
Table 5. Power Requirements
Parameter Specifications
Power supply 90–264 VAC 50/60 Hz
Maximum current draw per system 10A per power supply
Maximum power consumption 1920W (high Line) 900 (low line)