Dell PowerEdge R210 Specifications

Browse online or download Specifications for Networking Dell PowerEdge R210. Dell PowerEdge R210 Specifications [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Technical Guide
1-socket 1U rack
server providing
the features you
need without a
lot of the
unnecessary
extras.
Dell PowerEdge R210
Page view 0
1 2 3 4 5 6 ... 71 72

Summary of Contents

Page 1 - Dell PowerEdge R210

Technical Guide 1-socket 1U rack server providing the features you need without a lot of the unnecessary extras.

Page 2

Dell PowerEdge R210 Technical Guide 10 Feature R210 R200 (Predecessors) R310 (Next level up) RAID See Optional Storage Controller row above S

Page 3 - Table of Contents

Dell PowerEdge R210 Technical Guide 11 2 New Technologies 2.1 Overview A number of new technologies are used in the PowerEdge R210, including: •

Page 4

Dell PowerEdge R210 Technical Guide 12 Table 2. Comparison Overview PERC S100 and S300 Feature/Spec S100 S300 Interface 3Gb SATA (SATA II) 3G

Page 5

Dell PowerEdge R210 Technical Guide 13 up-to-date information, see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com. 2.

Page 6 - Figures

Dell PowerEdge R210 Technical Guide 14 3 System Overview Table 4. Product Feature Summary Feature Product Description Form Factor Rack Proce

Page 7 - 1 Product Comparison

Dell PowerEdge R210 Technical Guide 15 Feature Product Description Intel® PRO/ 1000PT Single Port Adapter, Gigabit Ethernet NIC, PCIe x1 Intel®

Page 8

Dell PowerEdge R210 Technical Guide 16 4 Mechanical 4.1 Chassis Description The PowerEdge R210 is a 1-socket 1U server. The configuration detail

Page 9

Dell PowerEdge R210 Technical Guide 17 Figure 1. Server Dimensions * Zb goes to the nominal rear wall external surface where the motherboard I

Page 10

Dell PowerEdge R210 Technical Guide 18 4.4 Back Panel View and Features Figure 3. Back Panel View 4.5 Power Supply Indicators 4.5.1 Power Butt

Page 11 - 2 New Technologies

Dell PowerEdge R210 Technical Guide 19 4.7 Side View Figure 5. Side View

Page 12

Dell PowerEdge R210 Technical Guide 2 This document is for informational purposes only. Dell reserves the right to make changes without

Page 13 - 2.2.3 eSATA

Dell PowerEdge R210 Technical Guide 20 4.8 Internal Chassis View Figure 6. Internal Chassis View

Page 14 - 3 System Overview

Dell PowerEdge R210 Technical Guide 21 4.9 Rails ReadyRails™ static rails for tool-less mounting in 4-post racks with square or unthreaded round

Page 15

Dell PowerEdge R210 Technical Guide 22 4.10 Fans There are three system fans located in the middle of the system. Figure 9. System Fans 4.11 Co

Page 16 - 4 Mechanical

Dell PowerEdge R210 Technical Guide 23 Table 7. TPM Pin Signals Pin SIGNAL Pin SIGNAL 1 TPM_PRES_N 20 I2C_TPM_SCL 2 LPC_LAD0 19 P3V3

Page 17

Dell PowerEdge R210 Technical Guide 24 4.12.6 Secure Mode BIOS has the ability to enter a secure boot mode via setup. This mode includes the opt

Page 18 - 4.6 NIC Indicators

Dell PowerEdge R210 Technical Guide 25 Figure 12. Battery on Motherboard 4.15 Field Replaceable Units (FRU) The planar contains a 16K x 8 seria

Page 19 - 4.7 Side View

Dell PowerEdge R210 Technical Guide 26 5 Power, Thermal, Acoustic 5.1 Power Supplies The base system includes a single 250W power supply. This u

Page 20 - 4.8 Internal Chassis View

Dell PowerEdge R210 Technical Guide 27 5.3 Environmental Specifications 5.3.1 Temperature Operating: 10° to 35°C (50° to 95°F) with a maximum

Page 21 - 4.9 Rails

Dell PowerEdge R210 Technical Guide 28 5.4 Power Supply Unit (PSU) Specifications Table 10. PSU Specifications Feature Non Redundant PSU Dimens

Page 22 - 4.12 Security

Dell PowerEdge R210 Technical Guide 29 • Optimized Ventilation. R210 chassis has a custom ventilation design for optimized air flow path. Each c

Page 23 - 4.12.5 Intrusion Alert

Dell PowerEdge R210 Technical Guide 3 Table of Contents 1 Product Comparison ...

Page 24 - 4.14 Battery

Dell PowerEdge R210 Technical Guide 30 bottom at 75 cm from the floor. The acoustic transducer is at front bystander position, ref ISO7779 (1999)

Page 25

Dell PowerEdge R210 Technical Guide 31 6 Processors 6.1 Overview The PowerEdge R210 is a 1S, entry-level server based on the Intel FCLGA1156 to

Page 26 - 5 Power, Thermal, Acoustic

Dell PowerEdge R210 Technical Guide 32 7 Memory 7.1 Overview Features of the PowerEdge R210 memory include: • 2 channels per processor • Suppo

Page 27

Dell PowerEdge R210 Technical Guide 33 System Capacity System Memory Speed DIMM Speed DIMM_TECH DIMM Capacity NUM_DIMM Slot NUM_Rank Data Width

Page 28 - 5.6 Thermal

Dell PowerEdge R210 Technical Guide 34 8 Chipset 8.1 Overview The PowerEdge R210 planar incorporates the Intel Ibex Peak as PCH chipset. The Ibe

Page 29 - 5.7 Acoustics

Dell PowerEdge R210 Technical Guide 35 8.7 Low Pin Count (LPC) Interface The Ibex Peak implements an LPC Interface as described in the LPC 1.1 Sp

Page 30

Dell PowerEdge R210 Technical Guide 36 8.12 Real-Time Clock (RTC) The Ibex Peak contains a real-time clock with 256 bytes of battery-backed RAM.

Page 31 - 6 Processors

Dell PowerEdge R210 Technical Guide 37 8.15.4 Function Disable The Ibex Peak provides the ability to disable the following integrated functions:

Page 32 - 7 Memory

Dell PowerEdge R210 Technical Guide 38 8.19 JTAG Boundary-Scan Ibex Peak adds the industry standard JTAG interface and enables Boundary-Scan in p

Page 33 - 7.7 RAID

Dell PowerEdge R210 Technical Guide 39 9 BIOS 9.1 Overview The following features are supported by BIOS: • System BIOS • System Setup • Onboa

Page 34 - 8 Chipset

Dell PowerEdge R210 Technical Guide 4 5.7 Acoustics ... 29 6 Proce

Page 35 - 8.11 USB Interface

Dell PowerEdge R210 Technical Guide 40 • AC recovery staggering Power-Up • DIMM mismatch checking • Support for multiple power profiles: • St

Page 36 - 8.13 GPIO

Dell PowerEdge R210 Technical Guide 41 9.3.2 Power Saving BIOS Setting (OS Control) Intel processors support Demand Based Switching (DBS) which

Page 37 - 8.15.4 Function Disable

Dell PowerEdge R210 Technical Guide 42 USB wake Generic N/A This feature is not supported on this system since the S1 state is not supported. DBS

Page 38 - 8.19 JTAG Boundary-Scan

Dell PowerEdge R210 Technical Guide 43 10 I/O Slots 10.1 Overview The PowerEdge R210 system provides: • Riser support x16 PCIe card (Gen2 link x

Page 39 - 9 BIOS

Dell PowerEdge R210 Technical Guide 44 Figure 14. SAS 6/iR Adapter Card Installed 10.2 PCI Devices Xeon 3400 Series CPU PCI devices include:

Page 40 - 9.3 Power Management Modes

Dell PowerEdge R210 Technical Guide 45 • Core Addressing Mapping, Intel VT-d, System Management • Core Semaphore and Scratchpad Registers • Co

Page 41 - 9.3.3 Maximum Performance

Dell PowerEdge R210 Technical Guide 46 Table 18. PCI Card Dimensions Link Width Height Length x1 Standard height, half length card 111.15 mm

Page 42

Dell PowerEdge R210 Technical Guide 47 10.3 Boot Order The PowerEdge R210 supports only 1 PCIe x8 slot. 10.4 NICs There is Broadcom 5716 chip on

Page 43 - 10 I/O Slots

Dell PowerEdge R210 Technical Guide 48 11 Storage 11.1 Overview The PowerEdge R210 supports up to 2 HDDS: • 2 x 2.5”/ 3.5” cabled SATA or SSD fr

Page 44 - 10.2 PCI Devices

Dell PowerEdge R210 Technical Guide 49 11.3 RAID Configurations Table 21. RAID Configurations Non-Mixed Drives, all SATA, all SSD, or ALL

Page 45

Dell PowerEdge R210 Technical Guide 5 11 Storage ... 48 11.

Page 46 - PCIe x4 1 1

Dell PowerEdge R210 Technical Guide 50 11.5 Tape Drives Table 22. Supported Tape Drives PV DAS PowerVault™ MD1000 PowerVault™ MD3000 PowerVau

Page 47 - 10.4 NICs

Dell PowerEdge R210 Technical Guide 51 12 Video and Audio 12.1 Video Matrox® G200eW w/ 8MB memory integrated in Winbond® WPCM450 (BMC controller)

Page 48 - 11 Storage

Dell PowerEdge R210 Technical Guide 52 13 Rack Information 13.1 Overview The ReadyRails™ static rail system for the R210 provides tool-free suppo

Page 49 - 11.3 RAID Configurations

Dell PowerEdge R210 Technical Guide 53 14 Operating Systems For the most up-to-date information, see the Operating System Support Matrix for Dell

Page 50 - 11.5 Tape Drives

Dell PowerEdge R210 Technical Guide 54 Table 25. Supported Linux Operating Systems Operating Systems x86 or x64 Installation Factory Install L

Page 51 - 12 Video and Audio

Dell PowerEdge R210 Technical Guide 55 15 Virtualization Table 26. Supported Virtualization OS Virtualization OS Install Method VMware® ESX 4 u

Page 52 - 13 Rack Information

Dell PowerEdge R210 Technical Guide 56 16 Systems Management 16.1 Overview Dell delivers open, flexible, and integrated solutions that help you r

Page 53 - 14 Operating Systems

Dell PowerEdge R210 Technical Guide 57 • Server Update Utility: In addition to the Systems Management Tools and Documentation and Dell Managemen

Page 54

Dell PowerEdge R210 Technical Guide 58 Table 27. Unified Server Configurator Features and Description Feature Description Faster O/S Installati

Page 55 - 15 Virtualization

Dell PowerEdge R210 Technical Guide 59 flash partition. A more detailed feature list for iDRAC6 Enterprise and vFlash is included in the followin

Page 56 - 16 Systems Management

Dell PowerEdge R210 Technical Guide 6 Table 17. I/O Slot Information ... 45 Table 18

Page 57 - • Dell Lifecycle Controller

Dell PowerEdge R210 Technical Guide 60 Feature BMC iDRAC6 Express iDRAC6 Enterprise vFlash Media capture Boot capture    Serial-ove

Page 58 - 16.6 iDRAC6 Enterprise

Dell PowerEdge R210 Technical Guide 61 17 Peripherals 17.1 USB All PowerEdge systems have a minimum of 2 front-accessible USB 2.0 compliant port

Page 59

Dell PowerEdge R210 Technical Guide 62 17.3 External Storage Table 30. External Storage External Optical Drive (Optional) USB DVD-ROM PowerVaul

Page 60

Dell PowerEdge R210 Technical Guide 63 18 Packaging Options Options for single pack and multipack are available. Multipack will support 4 units i

Page 61 - 17 Peripherals

Dell PowerEdge R210 Technical Guide 64 Figure 16. Packaging

Page 62 - 17.3 External Storage

Dell PowerEdge R210 Technical Guide 65 Appendix A. Regulatory Certifications • FCC (U.S. only) Class A • ICES (Canada) Class A • CE Mark (EN

Page 63 - 18 Packaging Options

Dell 66 PowerEdge R210 Technical Guide Appendix B. R210 Volatility Tables Table 33. PowerEdge R210 Volatility Non-Vol-atile Vol-atile RAM Refer-

Page 64 - Figure 16. Packaging

Dell 67 PowerEdge R210 Technical Guide Non-Vol-atile Vol-atile RAM Refer-ence Design-ator Qty Size Type iDRAC6 SDRAM Y U_IBMC_MEM 1 128MB

Page 65

Dell 68 PowerEdge R210 Technical Guide Table 34. Volatility: Data Writing and Purpose Can user programs or operating system write data to it duri

Page 66

Dell 69 PowerEdge R210 Technical Guide Can user programs or operating system write data to it during normal operation? Purpose? Chipset CMOS No

Page 67

Dell PowerEdge R210 Technical Guide 7 1 Product Comparison Dell aims to add value to your business by including the features you need without a

Page 68

Dell 70 PowerEdge R210 Technical Guide How is data input to this memory? Managed Services Repository: Various partitions are loaded using vendor

Page 69

Dell 71 PowerEdge R210 Technical Guide Table 36. Methodology for Memory Protection and Clearing How is this memory write protected? How is the

Page 70

Dell 72 PowerEdge R210 Technical Guide TPM Binding EEPROM (on China planar only) Locked by BIOS from physical access by anyone after boot Not applic

Page 71

Dell PowerEdge R210 Technical Guide 8 Table 1. Comparison of PowerEdge Server Features Feature R210 R200 (Predecessors) R310 (Next level up)

Page 72

Dell PowerEdge R210 Technical Guide 9 Feature R210 R200 (Predecessors) R310 (Next level up) Embedded HD Controller Chipset based SATA Chipset

Comments to this Manuals

No comments