Technical Guide 1-socket 1U rack server providing the features you need without a lot of the unnecessary extras.
Dell PowerEdge R210 Technical Guide 10 Feature R210 R200 (Predecessors) R310 (Next level up) RAID See Optional Storage Controller row above S
Dell PowerEdge R210 Technical Guide 11 2 New Technologies 2.1 Overview A number of new technologies are used in the PowerEdge R210, including: •
Dell PowerEdge R210 Technical Guide 12 Table 2. Comparison Overview PERC S100 and S300 Feature/Spec S100 S300 Interface 3Gb SATA (SATA II) 3G
Dell PowerEdge R210 Technical Guide 13 up-to-date information, see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com. 2.
Dell PowerEdge R210 Technical Guide 14 3 System Overview Table 4. Product Feature Summary Feature Product Description Form Factor Rack Proce
Dell PowerEdge R210 Technical Guide 15 Feature Product Description Intel® PRO/ 1000PT Single Port Adapter, Gigabit Ethernet NIC, PCIe x1 Intel®
Dell PowerEdge R210 Technical Guide 16 4 Mechanical 4.1 Chassis Description The PowerEdge R210 is a 1-socket 1U server. The configuration detail
Dell PowerEdge R210 Technical Guide 17 Figure 1. Server Dimensions * Zb goes to the nominal rear wall external surface where the motherboard I
Dell PowerEdge R210 Technical Guide 18 4.4 Back Panel View and Features Figure 3. Back Panel View 4.5 Power Supply Indicators 4.5.1 Power Butt
Dell PowerEdge R210 Technical Guide 19 4.7 Side View Figure 5. Side View
Dell PowerEdge R210 Technical Guide 2 This document is for informational purposes only. Dell reserves the right to make changes without
Dell PowerEdge R210 Technical Guide 20 4.8 Internal Chassis View Figure 6. Internal Chassis View
Dell PowerEdge R210 Technical Guide 21 4.9 Rails ReadyRails™ static rails for tool-less mounting in 4-post racks with square or unthreaded round
Dell PowerEdge R210 Technical Guide 22 4.10 Fans There are three system fans located in the middle of the system. Figure 9. System Fans 4.11 Co
Dell PowerEdge R210 Technical Guide 23 Table 7. TPM Pin Signals Pin SIGNAL Pin SIGNAL 1 TPM_PRES_N 20 I2C_TPM_SCL 2 LPC_LAD0 19 P3V3
Dell PowerEdge R210 Technical Guide 24 4.12.6 Secure Mode BIOS has the ability to enter a secure boot mode via setup. This mode includes the opt
Dell PowerEdge R210 Technical Guide 25 Figure 12. Battery on Motherboard 4.15 Field Replaceable Units (FRU) The planar contains a 16K x 8 seria
Dell PowerEdge R210 Technical Guide 26 5 Power, Thermal, Acoustic 5.1 Power Supplies The base system includes a single 250W power supply. This u
Dell PowerEdge R210 Technical Guide 27 5.3 Environmental Specifications 5.3.1 Temperature Operating: 10° to 35°C (50° to 95°F) with a maximum
Dell PowerEdge R210 Technical Guide 28 5.4 Power Supply Unit (PSU) Specifications Table 10. PSU Specifications Feature Non Redundant PSU Dimens
Dell PowerEdge R210 Technical Guide 29 • Optimized Ventilation. R210 chassis has a custom ventilation design for optimized air flow path. Each c
Dell PowerEdge R210 Technical Guide 3 Table of Contents 1 Product Comparison ...
Dell PowerEdge R210 Technical Guide 30 bottom at 75 cm from the floor. The acoustic transducer is at front bystander position, ref ISO7779 (1999)
Dell PowerEdge R210 Technical Guide 31 6 Processors 6.1 Overview The PowerEdge R210 is a 1S, entry-level server based on the Intel FCLGA1156 to
Dell PowerEdge R210 Technical Guide 32 7 Memory 7.1 Overview Features of the PowerEdge R210 memory include: • 2 channels per processor • Suppo
Dell PowerEdge R210 Technical Guide 33 System Capacity System Memory Speed DIMM Speed DIMM_TECH DIMM Capacity NUM_DIMM Slot NUM_Rank Data Width
Dell PowerEdge R210 Technical Guide 34 8 Chipset 8.1 Overview The PowerEdge R210 planar incorporates the Intel Ibex Peak as PCH chipset. The Ibe
Dell PowerEdge R210 Technical Guide 35 8.7 Low Pin Count (LPC) Interface The Ibex Peak implements an LPC Interface as described in the LPC 1.1 Sp
Dell PowerEdge R210 Technical Guide 36 8.12 Real-Time Clock (RTC) The Ibex Peak contains a real-time clock with 256 bytes of battery-backed RAM.
Dell PowerEdge R210 Technical Guide 37 8.15.4 Function Disable The Ibex Peak provides the ability to disable the following integrated functions:
Dell PowerEdge R210 Technical Guide 38 8.19 JTAG Boundary-Scan Ibex Peak adds the industry standard JTAG interface and enables Boundary-Scan in p
Dell PowerEdge R210 Technical Guide 39 9 BIOS 9.1 Overview The following features are supported by BIOS: • System BIOS • System Setup • Onboa
Dell PowerEdge R210 Technical Guide 4 5.7 Acoustics ... 29 6 Proce
Dell PowerEdge R210 Technical Guide 40 • AC recovery staggering Power-Up • DIMM mismatch checking • Support for multiple power profiles: • St
Dell PowerEdge R210 Technical Guide 41 9.3.2 Power Saving BIOS Setting (OS Control) Intel processors support Demand Based Switching (DBS) which
Dell PowerEdge R210 Technical Guide 42 USB wake Generic N/A This feature is not supported on this system since the S1 state is not supported. DBS
Dell PowerEdge R210 Technical Guide 43 10 I/O Slots 10.1 Overview The PowerEdge R210 system provides: • Riser support x16 PCIe card (Gen2 link x
Dell PowerEdge R210 Technical Guide 44 Figure 14. SAS 6/iR Adapter Card Installed 10.2 PCI Devices Xeon 3400 Series CPU PCI devices include:
Dell PowerEdge R210 Technical Guide 45 • Core Addressing Mapping, Intel VT-d, System Management • Core Semaphore and Scratchpad Registers • Co
Dell PowerEdge R210 Technical Guide 46 Table 18. PCI Card Dimensions Link Width Height Length x1 Standard height, half length card 111.15 mm
Dell PowerEdge R210 Technical Guide 47 10.3 Boot Order The PowerEdge R210 supports only 1 PCIe x8 slot. 10.4 NICs There is Broadcom 5716 chip on
Dell PowerEdge R210 Technical Guide 48 11 Storage 11.1 Overview The PowerEdge R210 supports up to 2 HDDS: • 2 x 2.5”/ 3.5” cabled SATA or SSD fr
Dell PowerEdge R210 Technical Guide 49 11.3 RAID Configurations Table 21. RAID Configurations Non-Mixed Drives, all SATA, all SSD, or ALL
Dell PowerEdge R210 Technical Guide 5 11 Storage ... 48 11.
Dell PowerEdge R210 Technical Guide 50 11.5 Tape Drives Table 22. Supported Tape Drives PV DAS PowerVault™ MD1000 PowerVault™ MD3000 PowerVau
Dell PowerEdge R210 Technical Guide 51 12 Video and Audio 12.1 Video Matrox® G200eW w/ 8MB memory integrated in Winbond® WPCM450 (BMC controller)
Dell PowerEdge R210 Technical Guide 52 13 Rack Information 13.1 Overview The ReadyRails™ static rail system for the R210 provides tool-free suppo
Dell PowerEdge R210 Technical Guide 53 14 Operating Systems For the most up-to-date information, see the Operating System Support Matrix for Dell
Dell PowerEdge R210 Technical Guide 54 Table 25. Supported Linux Operating Systems Operating Systems x86 or x64 Installation Factory Install L
Dell PowerEdge R210 Technical Guide 55 15 Virtualization Table 26. Supported Virtualization OS Virtualization OS Install Method VMware® ESX 4 u
Dell PowerEdge R210 Technical Guide 56 16 Systems Management 16.1 Overview Dell delivers open, flexible, and integrated solutions that help you r
Dell PowerEdge R210 Technical Guide 57 • Server Update Utility: In addition to the Systems Management Tools and Documentation and Dell Managemen
Dell PowerEdge R210 Technical Guide 58 Table 27. Unified Server Configurator Features and Description Feature Description Faster O/S Installati
Dell PowerEdge R210 Technical Guide 59 flash partition. A more detailed feature list for iDRAC6 Enterprise and vFlash is included in the followin
Dell PowerEdge R210 Technical Guide 6 Table 17. I/O Slot Information ... 45 Table 18
Dell PowerEdge R210 Technical Guide 60 Feature BMC iDRAC6 Express iDRAC6 Enterprise vFlash Media capture Boot capture Serial-ove
Dell PowerEdge R210 Technical Guide 61 17 Peripherals 17.1 USB All PowerEdge systems have a minimum of 2 front-accessible USB 2.0 compliant port
Dell PowerEdge R210 Technical Guide 62 17.3 External Storage Table 30. External Storage External Optical Drive (Optional) USB DVD-ROM PowerVaul
Dell PowerEdge R210 Technical Guide 63 18 Packaging Options Options for single pack and multipack are available. Multipack will support 4 units i
Dell PowerEdge R210 Technical Guide 64 Figure 16. Packaging
Dell PowerEdge R210 Technical Guide 65 Appendix A. Regulatory Certifications • FCC (U.S. only) Class A • ICES (Canada) Class A • CE Mark (EN
Dell 66 PowerEdge R210 Technical Guide Appendix B. R210 Volatility Tables Table 33. PowerEdge R210 Volatility Non-Vol-atile Vol-atile RAM Refer-
Dell 67 PowerEdge R210 Technical Guide Non-Vol-atile Vol-atile RAM Refer-ence Design-ator Qty Size Type iDRAC6 SDRAM Y U_IBMC_MEM 1 128MB
Dell 68 PowerEdge R210 Technical Guide Table 34. Volatility: Data Writing and Purpose Can user programs or operating system write data to it duri
Dell 69 PowerEdge R210 Technical Guide Can user programs or operating system write data to it during normal operation? Purpose? Chipset CMOS No
Dell PowerEdge R210 Technical Guide 7 1 Product Comparison Dell aims to add value to your business by including the features you need without a
Dell 70 PowerEdge R210 Technical Guide How is data input to this memory? Managed Services Repository: Various partitions are loaded using vendor
Dell 71 PowerEdge R210 Technical Guide Table 36. Methodology for Memory Protection and Clearing How is this memory write protected? How is the
Dell 72 PowerEdge R210 Technical Guide TPM Binding EEPROM (on China planar only) Locked by BIOS from physical access by anyone after boot Not applic
Dell PowerEdge R210 Technical Guide 8 Table 1. Comparison of PowerEdge Server Features Feature R210 R200 (Predecessors) R310 (Next level up)
Dell PowerEdge R210 Technical Guide 9 Feature R210 R200 (Predecessors) R310 (Next level up) Embedded HD Controller Chipset based SATA Chipset