Dell PowerEdge Expandable RAID Controller 3 User's Guide Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 160
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
Installing and Configuring Hardware 51
5
Determine whether the Dirty Cache LED on the controller is illuminated.
For location of the LED, see Figure 4-8
If the LED is illuminated, replace the system cover, reconnect the
system to power, turn on the system, and repeat step 1 and step 2.
If the LED is not illuminated, continue with the next step.
6
Disconnect the data cables and battery cable from the PERC 6/i.
Remove any retention mechanism, such as a bracket screw, that might be
holding the PERC 6/i in the system, and gently lift the controller from the
system’s PCI-E slot.
Figure 4-8. Removing the PERC 6/i Adapter
1 bracket screw 3 dirty cache LED
2 PERC 6/i controller
2
3
1
Dell_PERC6.2_UG.book Page 51 Wednesday, June 24, 2009 6:08 PM
Page view 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 159 160

Comments to this Manuals