Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS User's Guide Page 181

  • Download
  • Add to my manuals
  • Print
  • Page
    / 292
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 180
Storage Management Message Reference 181
2293 The EMM has
failed.
Critical /
Failure / Error
Cause: The failure may
be caused by a loss of
power to the EMM.
The EMM self test may
also have identified a
failure. There could also
be a firmware problem
or a multi-bit error.
Action: Replace the
EMM. See the hardware
documentation for
information on
replacing the EMM.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2091
854
2294 A device has
been inserted.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
851
2295 A device has
been removed.
Critical /
Failure / Error
Cause: A device has
been removed and the
system is no longer
functioning in optimal
condition.
Action: Replace the
device.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2091
854
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Page view 180
1 2 ... 176 177 178 179 180 181 182 183 184 185 186 ... 291 292

Comments to this Manuals

No comments