184 Power Group
Power Profile Custom Fan Mgmt Setting
Power Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Name powerProfileCustomFanMgmtSetting
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.10
Description Defines the custom fan power and performance management
setting for the Custom power profile.
Syntax DellFanPowerPerformanceManagementType
Access Read-only
Table 8-1. Power Supply State Capabilities Unique
Variable Name:
DellPowerSupplyStateCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The power supply’s capabilities are unknown.
onlineCapable(2) The power supply can be disabled (offline, a binary
0 value) or enabled (online, a binary 1 value).
notReadyCapable(4) The power supply’s capabilities are not ready.
Table 8-2. Power Supply State Settings Unique
Variable Name:
DellPowerSupplyStateSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The power supply’s capabilities are unknown.
onLine(2) The power supply’s state is disabled (offline, a
binary 0 value) or enabled (online, a binary 1 value).
notReady(4) The power supply’s state is not ready.
fanFailure(8) The power supply fan has failed.
Page view 183