Dell OpenManage Server Administrator Version 7.0 User Manual Page 120

  • Download
  • Add to my manuals
  • Print
  • Page
    / 302
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 119
120 omconfig: Managing Components Using the Instrumentation Service
omconfig chassis currents or omconfig mainsystem currents
NOTE: This command is no longer available through Server Administrator.
omconfig chassis fans or omconfig mainsystem fans
Use the omconfig chassis fans or omconfig mainsystem fans command to
set fan probe warning thresholds. As with other components, you can view
both warning and failure threshold values, but you cannot set failure
thresholds. The system manufacturer sets the minimum and maximum
failure thresholds.
Valid Parameters for Fan Warning Thresholds
Table 4-5 s h ows the v alid parameters for setting fan warning thresholds:
Default Minimum and Maximum Warning Thresholds
NOTE: Systems that contain ESM3, ESM4, and BMC capabilities do not allow you to
set warning threshold values to default values.
To set both the upper and lower fan warning threshold values to the
recommended default value, type:
UEFI Boot Settings attribute=UefiBootSeq sequence=aliasname1,
aliasname2,..... aliasnameN
Table 4-5. omconfig chassis fans or omconfig chassis fans
name=value pair Description
index=<n> Number of the probe or probe index (must specify.)
warnthresh=default Sets minimum and maximum warning thresholds to default.
minwarnthresh=<n> Minimum warning threshold.
maxwarnthresh=<n> Maximum warning threshold.
Table 4-4. BIOS Setup Settings on PowerEdge yx2x Systems
(continued)
Group name=value pair 1
attribute=
name=value pair 2
setting=
Page view 119
1 ... 119 120 121 ... 302

Comments to this Manuals

No comments