Dell PowerEdge 1800 User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
4 Information Update
www.dell.com | support.dell.com
3
Click the
Monitor
tab.
The
Monitor Type
list box displays the monitors attached to your system.
NOTE: If a Remote Access Card (RAC) is installed in your system, the RAC appears as a third video
device in the Monitor Type list box. Use the scroll buttons in the Monitor Type list box to display
any additional monitor types.
NOTE: If Windows Server 2003 cannot identify the monitor type, the operating system identifies
the monitor as a "Plug and Play Monitor."
BIOS Version A01
New features were added to the A01 release of the system BIOS that are not present in the previous
release. As a result, flashing the BIOS back to the earlier release may cause unexpected system
behavior. Dell does not recommend that you revert your system to a previous BIOS release.
Adding a Second IDE Device to the IDE Controller Cable
The system board has one IDE controller and one IDE connector that is normally used to connect
an IDE optical device installed in the 5.25-inch drive bay. The System Setup program provides an
option to enable or disable the IDE controller, and the primary master optical device can be viewed
through the boot order in the System Setup program.
If a second IDE device, such as an IDE tape backup drive, is installed in the 5.25-inch peripheral
bay and is attached to the slave connector of the IDE cable, details of the second device can be
viewed only in the operating system and not the System Setup program.
Embedded SATA 2s Controller-to-CERC SATA 6-Channel
Upgrade Considerations
If you are presently using the embedded SATA 2s controller in a dual hard-drive configuration and
are upgrading to a CERC SATA 6-channel expansion card RAID array, you must first disable and
remove the embedded SATA 2s configuration.
NOTICE: Operating the system in a CERC 6-channel SATA RAID array with the embedded SATA 2s
controller enabled is not a supported configuration and can cause the operating system to malfunction
during shutdowns and other unpredictable results.
Follow the guidelines listed below if you are presently using an embedded SATA 2s controller
configuration and are upgrading to a CERC SATA 6-channel configuration.
1
Back up the data from the hard drives that the embedded SATA 2s controller is using.
The hard drives must be reinitialized for use with the CERC SATA 6-channel upgrade.
2
Disable the embedded SATA 2s controller in the System Setup program.
See "Using the System Setup Program" in the
User’s Guide
for additional information.
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 65 66

Comments to this Manuals