Dell PowerEdge VRTX User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
backplane expander board firmware, and the PowerEdge VRTX chassis infrastructure firmware. For the
latest versions of drivers and firmware, see Downloading Firmware and Drivers in this document.
Firmware Requirements
NOTE: Ensure that you have uninterrupted network connectivity. The update fails if the network
connectivity is interrupted during the process.
Each firmware upgrade process is described in detail in this document.
Table 1. Firmware Required for the Upgrade Procedure
Firmware Minimum Version File Type Installation Time
Shared PERC 8
Device Driver for
each server module
Windows:
6.802.19.0
ESXi 5.1:
06.802.71.00
Operating
system
dependent
Up to 10 minutes.
CMC Firmware 1.30 .bin Up to 10 minutes.
The process may take longer if you have a
secondary CMC installed. For dual CMC,
ensure two network cables are
connected.
Shared Hard Drive
Firmware
Depends on hard
drive type
.exe Up to 2 minutes.
Chassis
Infrastructure
Firmware
1.30 .bin Upto 25 minutes.
The process may take longer for dual
CMCs.
Shared PERC 8
Firmware
23.8.10-0059 .exe Up to 10 minutes.
The process may take longer for updating
both the Shared PERC 8 cards.
Backplane
Expander Board
Firmware
1.02 .exe Up to 2 minutes.
Downloading Firmware and Drivers
1. Go to dell.com/support/drivers.
2. Enter the Service Tag for the PowerEdge VRTX system in the Service Tag or Express Service Code
box and click Submit.
3. Under Refine Your Results, select the operating system.
Ensure that you select the correct operating system.
6
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 27 28

Comments to this Manuals