About Your System 105
E1229 CPU # VCORE
Regulator
failure.
Reseat CPU.
Specified processor
VCORE voltage regulator
has failed.
Reseat the processor(s).
See "Troubleshooting
Processors" on page 322.
If the problem persists,
see "Getting Help" on
page 361.
E122A CPU # VTT
Regulator
failure.
Reseat CPU.
Specified processor VTT
voltage regulator has failed.
Reseat the processor(s).
See "Troubleshooting
Processors" on page 322.
If the problem persists,
see "Getting Help" on
page 361.
E122C CPU Power
Fault. Power
cycle AC.
A power fault was detected
when powering up the
processor(s).
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
E122D Memory
Regulator #
Failed.
Reseat DIMMs.
One of the memory
regulators has failed.
Reseat the memory
modules. See
"Troubleshooting Blade
Memory" on page 319.
E122E On-board
regulator
failed. Call
support.
One of the on-board
voltage regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
E1310 Fan ## RPM
exceeding
range. Check
fan.
Speed of the specified fan is
outside of the intended
operating range.
See "Troubleshooting Fan
Modules" on page 315.
Table 1-26. LCD Status Messages
(continued)
Code Text Cause Corrective Actions