Dell PowerEdge T110 User Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 144
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
20 About Your System
System Messages
System messages appear on the screen to notify you of a possible problem
with the system.
NOTE: If you receive a system message not listed in the table, check the
documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.
Message Causes Corrective Actions
Alert! BMC not
responding.
Rebooting.
The BMC is not
responding to BIOS
communication either
because it is not
functioning properly or has
not completed
initialization. The system
reboots.
Wait for the system to reboot.
Alert! BMC not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The BMC is hung.
The BMC was remotely
reset while system was
booting.
After AC recovery, the
BMC takes longer than
normal to boot.
Remove AC power to the
system for 10 seconds and
restart the system.
Mayzie_HOM.book Page 20 Monday, August 31, 2009 9:33 PM
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 143 144