Dell PowerEdge T110 User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 144
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
About Your System 25
Memory odd/even
logic failure at
address,
read
value
expecting
value.
Faulty or improperly
installed memory modules.
See "Troubleshooting System
Memory" on page 113.
Memory
write/read
failure at
address
, read
value
expecting
value.
Faulty or improperly
installed memory modules.
See "Troubleshooting System
Memory" on page 113.
Memory set to
minimum
frequency.
The memory frequency
may be intentionally set
lower for power
conservation.
If not an intentional setting,
check any other system
messages for possible causes.
The current memory
configuration may support
only the minimum
frequency.
Ensure that your memory
configuration supports the
higher frequency. See "General
Memory Module Installation
Guidelines" on page 80.
Memory tests
terminated by
keystroke.
POST memory test was
terminated by pressing the
spacebar.
Information only.
MEMTEST lane
failure
detected on
x.
Invalid memory
configuration. A
mismatched memory
module is installed.
Ensure that the memory
modules are installed in a valid
configuration. See "General
Memory Module Installation
Guidelines" on page 80.
Message Causes Corrective Actions
Mayzie_HOM.book Page 25 Monday, August 31, 2009 9:33 PM