14 Information Update
TPM operation is
pending. Press I to
Ignore or M to
Modify to allow
this change and
reset the system.
WARNING: Modifying
could prevent
security.
Configuration change has
been requested.
Press I to continue system
boot. Press M to modify
the TPM setting and
restart.
Warning: Following
faulty DIMMs are
disabled:
DIMM n
1
n
2
Total memory size
is reduced.
Faulty or improperly seated
memory module(s).
DIMMs are disabled in
pairs, as indicated by the n
1
and n
2
. Check both
DIMMs for a possible fault.
See "Troubleshooting
System Memory" in the
Hardware Owner’s Manual.
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
A fatal system error
occurred and caused the
system to restart.
Check the SEL for
information that was
logged during the error.
See the applicable
troubleshooting section in
See "Troubleshooting Your
System" in the Hardware
Owner’s Manual. for any
faulty components
specified in the SEL.
Warning! No micro
code update loaded
for processor n
Micro code update failed. Update the BIOS firmware.
See "Getting Help" in the
Hardware Owner’s Manual.
Table 1-1. System Messages (continued)
Message Causes Corrective Actions