Page view 25
POST Codes SR870BN4 Error Reference Guide
Revision 1.0
20
Code Value (bit 8 = 1,
bits 11:4 shown below)
Module Display
0xF2 Memory Autoscan (stackless) North
SUB MODULES
BITS
15:12 11:8 7:4 3:0
Memory Autoscan
8 F 2 0
Pass1 Entry
8 F 2 1
Process Auto Scan Input
8 F 2 2
Execute Auto scan (C- code)
8 F 2 3
Process Auto Scan Output
North
0xF1 Recovery stackless North
0xF0 Reserved North
0xEF-0xEE Memory Autoscan C-code North
0xED-E8 Recovery C-Code
0xE8-0xE6 HOB North
0xE5-0xC1 Reserved North
0xC0 SALA to SALB/DXE handoff North
0xB0-0xBF Reserved North
0xAF-80 Reserved for SAL
MCA, INIT, PMI
North
0x7F to 0x60 SAL-B codes
SAL-B
SAL_C
SAL_F
South
South
South
0x60 SAL to EFI handoff South
0x5F to 0x50 EFI South
0x4F to 0x40 ACPI South
7.2.2 Specific POST code Modules
7.2.2.1 SAL-A Module
The SAL-A POST codes are defined in the following table.
Table 6. SAL-A POST Codes (BSP Only)
Code Number Meaning Display
0x8FE0 Reset Condition North
0x8FD0 Node BSP selection North
0x8FC0 Early node init (SNCPEIM) North
0x8FB0 Processor health/setup (CVDR PEIM) North
0x8FA0 PAL/FW health status North
0x8F70 Memory Initialization Entry North
0x8F71 RAC Initialization (Mem_DoRacInitialization()) North
Page view 25