Dell PowerEdge 7250 User's Guide Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
POST Codes SR870BN4 Error Reference Guide
Revision 1.0
24
0x87E5 BSP + APs Set PMI entry point
PAL Call (pal_pmi_entrypoint_20).
South
0x07E5 BSP + APs Hang if ERROR. South
0x87E4 BSP + APs PAL Cache Summary by PAL Call (pal_cache_summary_04). South
0x07E4 BSP + APs Hang if ERROR South
0x87E3 BSP + APs PAL Cache Information set. PAL Call cache_info_02. South
0x07E3 BSP + APs Hang, if ERROR. South
0x87E2 BSP + APs pal_mc_register_mem_1b/find CPU min state pointer.
Should be able now to initialize health,bsp/ap,cache size line size,
sapic ver, and cpuid. Set minimal state save area, BSPSTORE
and SP.
South
0x87E1 BSP + APs Cache flush shadow. South
0x07E1 BSP + APs Hang if ERROR. South
0x87E0 BSP + APs Program IVA,ITR(0) for PAL,SAL runtime code & data area
cr.iva/cr.ifa/cr.itir/itr[r0].
South
0x87DF BSP + APs Clear semaphore and wait for all CPUs to synchronize. South
0x87DE BSP + APs Sort CPU health. Already sorted for 2nd level BSP selection. Store
BSP/AP flag for respective CPU.
South
0x87DD APs Setup for interrupt wakeup reinitialization of BSPSTORE and SP if
needed. Wait for interrupt wakeup.
South
0x87DC BSP only Switch to virtual address Control register programming SET in PSR
bn(44), it(36), rt(27), dt(17), ic(13) .
Clear task priority register=cr.tpr.
Clear interruption function state register-cr.ifs.
Set legacy BIOS cs.base and ss.base.
Set es,ds,fs,gs=0 with 4G limit Legacy BIOS module (eip).
Give control at xxxx:e05b to IA-32 code.
South
7.2.2.3 SAL-F Module
Table 8. SAL-F POST Codes
Code Value BSP,
APs,
Both
Meaning Display
0x87BF BSP First check point. Check point in v6b00_83_ip2x. Update EBDA entry inside
SST Create EFI memory descriptor Update SST checksum.
South
0x87BE BSP Check point near v6b00_83_5 Search FIT for ACPI module
(SAL_C_module_17) and get size, align, scratch buff size.
South
0x07BE BSP Hang if ERROR. South
0x87BD BSP Load image by module type (sal_c_module_17). Use PELoader. South
0x07BD BSP Hang if not found. Get entry point, and GP value. South
0x87BC BSP Load image by module type (sal_c_module_17). Flush cache. South
0x07BC BSP Hang on ERROR.
Build MP & ACPI table.
South
0x87BB BSP Initialize memory manager(0x0) by call to SAL_C. South
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 43 44

Comments to this Manuals