Fabric Watch Administrator’s Guide
Environment monitoring
8
Environment monitoring setting guidelines
Use Environment Class default settings. Temperature settings are switch-dependent and there is
no need to alter them. The default alarm configuration, sending alerts to the error log and SNMP, is
sufficient.
Environment class default settings
Table 24 provides default Environment class settings for all switches. Check the appropriate
hardware reference manual for differences in actual environmental requirements.
NOTE
Fabric Watch no longer supports fan monitoring. Event Manager (EM) now manages fan monitoring
and the switch status is calculated based on the fan status reported by EM.
TABLE 24 Environment class default settings
Area Description Default threshold
settings
Default alarm settings Threshold state
Temperature Monitors switch
temperature in
Celsius
Unit: degrees C
Time Base: none
Brocade 200E
Low: 0
High: 60
Buffer: 10
Below: 3
Above: 3
(Same setting for all
devices)
Out-of-range
Out-of-range
(Same setting for all
devices except
Brocade DCX-4S)
Brocade 300
Low: 0
High: 50
Buffer: 10
Brocade 5100
Low: 0
High: 63
Buffer: 10
Brocade 5300
Low: 0
High: 48
Buffer: 10
Brocade 7500
Low: 0
High: 63
Buffer: 10
Brocade 7600
Low: 0
High: 63
Buffer: 10
Brocade 7800
Low: 0
High: 58
Buffer: 10