Dell PowerEdge R815 Specifications Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 59
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
Dell
Dell PowerEdge R815 Technical Guide
22
Maximum shock
Operating
Half sine shock in all operational orientations of 31 G +/- 5%
with a pulse duration of 2.6 ms +/-10%
Storage
Half sine shock on all six sides of 71 G +/- 5% with a pulse
duration of 2 ms +/-10%
Square wave shock on all six sides of 27 G with velocity change
@ 235 in/sec or greater
Altitude
Operating
-16 to 3048 m (-50 to 10,000 ft)
Note: For altitudes above 2950 feet, the maximum operating
temperature is derated 1°F/550 ft.
Storage
-16 to 10,600 m (-50 to 35,000 ft)
4.6 ENERGY STAR
®
Compliance
ENERGY STAR qualified configurations can be accessed from the ENERGY STAR
Compliance results landing page on Dell.com.
4.7 Thermal
The R815 thermal solution includes:
Energy-efficient fans with lower power consumption per fan than previous 2U
products.
Custom air baffling directs airflow through the components to maintain proper
cooling while improved chassis ventilation ensures sufficient airflow to allow
the AMD G34 feature set to be deployed in a 2U chassis.
Custom-designed heat sinks maintain CPU and IOB chip temperatures within
thermal design targets.
Highly Optimized Fan Control Algorithm:
Base fan speeds are a function of hardware configuration and ambient
temperature to minimize airflow for a given environment.
Closed-loop PID control algorithms are used for both CPU and DIMMs to
maintain appropriate thermal margin.
Double-refresh switching allows for DIMM temperature excursions up to
95°C while maintaining performance and thermal design targets as follows:
o The R815 thermal algorithm monitors the thermal sensor on each
DIMM to maintain DIMM temperatures below the typical 85°C
specification in normal operating conditions.
o Under extreme operating conditions the thermal algorithm can
switch the DIMMs into Double-Refresh mode allowing an additional
10°C of thermal headroom. In Double-Refresh mode DIMMs are
allowed to operate as high as 95°C.
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 58 59

Comments to this Manuals

No comments