PowerEdge R415 Technical Guide The PowerEdge R415 offers enterprise-class features with a balance of processing power and
Dell 10 PowerEdge R415 Technical Guide Feature SC1435 (predecessor) R410 R415 R610 Power Supplies Non-redundant 600W Auto Ranging (90V~264V) Non-red
Dell 11 PowerEdge R415 Technical Guide 2 System Overview Table 2 provides an overview of the PowerEdge R415 server features. Table 2. Product Featur
Dell 12 PowerEdge R415 Technical Guide Feature Technical Specification Communications Optional add-in NICs: Intel® 10GBase-T Copper Single Port NIC, P
Dell 13 PowerEdge R415 Technical Guide Feature Technical Specification Operating Systems Microsoft® Windows® Small Business Server 2008 Microsoft® Win
Dell 14 PowerEdge R415 Technical Guide 3 Mechanical 3.1 Chassis Description The PowerEdge R415 chassis was designed to deliver a value-based, high-p
Dell 15 PowerEdge R415 Technical Guide 3.3 Front Panel View and Features The PowerEdge R415 is available in two chassis configurations: cabled hard dr
Dell 16 PowerEdge R415 Technical Guide Figure 6. Back View (Redundant Power Supply) See the Back-Panel Features and Indicators section in the About
Dell 17 PowerEdge R415 Technical Guide 3.8 Internal Chassis View Figure 9 shows the internal chassis view. Figure 9. Internal Chassis View 3.9 Rail
Dell 18 PowerEdge R415 Technical Guide For more information on rails, see section 13.2. 3.10 Rack View 3.10.1 Sliding Rails See Figure 10 and Figure
Dell 19 PowerEdge R415 Technical Guide Figure 12. R415 Mounted in A4 Static Rails (2-Post Center Mount Configuration) 3.11 Fans There are total of s
Dell ii PowerEdge R415 Technical Guide This document is for informational purposes only. Dell reserves the right to make changes without further noti
Dell 20 PowerEdge R415 Technical Guide 3.12.1 LED Panel Configuration Figure 14 and Figure 15 show the LED panel. Figure 14. LED panel Configuratio
Dell 21 PowerEdge R415 Technical Guide The LCD panel is a graphics display controlled by iDRAC6. Error codes can be sent to the display by either iDRA
Dell 22 PowerEdge R415 Technical Guide 3.13.7 Secure Mode BIOS can enter a secure boot mode through setup. This mode includes the option to lock out
Dell 23 PowerEdge R415 Technical Guide 4 Power, Thermal, Acoustic 4.1 Power Supplies The PowerEdge R415 is powered by either a non-redundant 480W po
Dell 24 PowerEdge R415 Technical Guide Feature Non-Redundant Power Supply Redundant Power Supply ambient operating range, the inrush current may reach
Dell 25 PowerEdge R415 Technical Guide Maximum Shock Operating Half sine shock in all operational orientations of 31G +/- 5% with a pulse duration of
Dell 26 PowerEdge R415 Technical Guide Table 7. Acoustical Performance Configuration @ 23 ± 2 °C Operating Mode LWA-UL (Bels) LpA (dBA) Prominent Ton
Dell 27 PowerEdge R415 Technical Guide 5 Processors 5.1 Overview The PowerEdge R415 utilizes the latest four- and six-core offerings from the AMD O
Dell 28 PowerEdge R415 Technical Guide Model Speed Power Cores L2/L3 Cache HyperTransport HyperTransport Multiplier Memory Speed Process 4180 2.6GHz 9
Dell 29 PowerEdge R415 Technical Guide 6 Memory 6.1 Overview The PowerEdge R415 uses DDR3 memory, providing a high-performance, high-speed memory int
Dell iii PowerEdge R415 Technical Guide Table of Contents 1 Product Comparison ...
Dell 30 PowerEdge R415 Technical Guide The following is not supported: Mixing of RDIMMs and UDIMMs Use of non-ECC UDIMMs For more information on
Dell 31 PowerEdge R415 Technical Guide System Capacity DIMM Slots 1 Socket Channel A Channel B UDIMM RDIMM A1 A3 A2 A4 DIMM speed System speed DIMM sp
Dell 32 PowerEdge R415 Technical Guide 7 Chipset 7.1 Overview The PowerEdge R415 planar incorporates a dual-IOB configuration using the AMD SR5670 ch
Dell 33 PowerEdge R415 Technical Guide 8 BIOS 8.1 Overview The PowerEdge R415 BIOS is based on the Dell BIOS core and supports the following feature
Dell 34 PowerEdge R415 Technical Guide 8.2 Supported ACPI States The following ACPI states are supported: ACPI compliance: S0, S4, S5 NO S1, S2,
Dell 35 PowerEdge R415 Technical Guide Feature Type Enable/Status/ Ctrl bit location Description ACPI mode, SMI handler owns power button events. Real
Dell 36 PowerEdge R415 Technical Guide Profile Description Maximum Performance DBPM Disabled (BIOS sets P-State to MAX) Memory frequency: Maximum Perf
Dell 37 PowerEdge R415 Technical Guide 9 Embedded NICs/LAN on Motherboard (LOM) The Broadcom® 5716 LOM chip is located on the PowerEdge R415 motherbo
Dell 38 PowerEdge R415 Technical Guide 10 I/O Slots 10.1 Overview The PowerEdge R415 includes a total of two PCI Express expansion slots as follows:
Dell 39 PowerEdge R415 Technical Guide Category Description Width Slot Priority Maximum Cards Qlogic® QLE2460 FC4 HBA, Single Port x4 Gen1 1 1 Qlo
Dell iv PowerEdge R415 Technical Guide 5.2 Features ...
Dell 40 PowerEdge R415 Technical Guide 10.2 Boot Order The boot order can be customized based on bootable devices detected by the BIOS. 10.3 NICs See
Dell 41 PowerEdge R415 Technical Guide 11 Storage 11.1 Overview The PowerEdge R415 supports up to four hard drives in one of the following configurati
Dell 42 PowerEdge R415 Technical Guide Factory Configuration Non-Mixed drives all SATA, all SAS, or all SSD; all 2.5” or all 3.5” Cabled/ Hot Plug Con
Dell 43 PowerEdge R415 Technical Guide Factory Configuration Non-Mixed drives all SATA, all SAS, or all SSD; all 2.5” or all 3.5” Cabled/ Hot Plug Con
Dell 44 PowerEdge R415 Technical Guide 11.5 LED Indicators Each disk drive carrier has two LED indicators visible from the front of the system. One is
Dell 45 PowerEdge R415 Technical Guide 12 Video The PowerEdge R415 is equipped with a Matrox® G200eW with 8 MB memory integrated in the Nuvoton® WPCM4
Dell 46 PowerEdge R415 Technical Guide 13 Rack Information 13.1 Overview The ReadyRails™ sliding and static rail systems for the R415 provide tool-les
Dell 47 PowerEdge R415 Technical Guide are mounted into the brackets. The design of the brackets has been optimized to limit the forward shift of the
Dell 48 PowerEdge R415 Technical Guide Figure 20. R415 Static Rails One key factor in selecting the proper rails is identifying the type of rack in
Dell 49 PowerEdge R415 Technical Guide Table 19. Rail Adjustability Ranges and Depth Product Rail ID Mounting Interface Rail Type Rail Adjustability
Dell v PowerEdge R415 Technical Guide 15.1 Overview/Description ... 51
Dell 50 PowerEdge R415 Technical Guide 14 Operating Systems and Virtualization For detailed information, see the following: • Operating System Suppor
Dell 51 PowerEdge R415 Technical Guide 15 Systems Management 15.1 Overview/Description Dell aims on delivering open, flexible, and integrated solution
Dell 52 PowerEdge R415 Technical Guide Remote Access Controller) is responsible for acting as an interface between the host system and its management
Dell 53 PowerEdge R415 Technical Guide • Graphical web interface • Standard-based interfaces • Server Sensor monitoring and fault alerting • Se
Dell 54 PowerEdge R415 Technical Guide Feature BMC iDRAC6 Express iDRAC6 Enterprise vFlash Media Security and Authentication Role-based Authority
Dell 55 PowerEdge R415 Technical Guide 16 USB Peripherals The PowerEdge R415 supports the following USB devices: USB key (bootable) Keyboard (on
Dell 56 PowerEdge R415 Technical Guide Appendix A. Statement of Volatility The Dell PowerEdge R415 contains both volatile and non-volatile (NV) compo
Dell 57 PowerEdge R415 Technical Guide LOM (LAN [Network Interface] on Motherboard) Memory Details Size: 4Mb (1MB) Type: [e.g., Flash PROM, EEPROM
Dell 58 PowerEdge R415 Technical Guide TPM (Trusted Platform Module; For boards shipped outside of China; Boards sold to destinations in China do not
Dell 59 PowerEdge R415 Technical Guide Server BMC (Baseboard Management Controller) Firmware Flash Memory Details Size: 16MB Flash Type: [e.g., Flash
Dell vi PowerEdge R415 Technical Guide Figure 6. Back View (Redundant Power Supply) ... 16 F
Dell 60 PowerEdge R415 Technical Guide Appendix B. Certifications B.1 Regulatory Certifications Regulatory model: E07S Regulatory Type: E07S003 Regu
Dell 61 PowerEdge R415 Technical Guide B.3 Electromagnetic Compatibility The product has been certified and bears the Mark, as applicable, of the E
Dell 62 PowerEdge R415 Technical Guide Appendix C. Additional Information and Options The PowerEdge R415 system conforms to the industry standards de
Dell 63 PowerEdge R415 Technical Guide Standard URL for information and specifications Unified Extensible Firmware Interface Specification, v2.1 USB U
Dell 7 PowerEdge R415 Technical Guide 1 Product Comparison 1.1 Overview The Dell™ PowerEdge™ R415 is a 2-socket 1U rack server that is designed to d
Dell 8 PowerEdge R415 Technical Guide The optional Lifecycle Controller helps you perform system diagnostics, hardware configuration, and system deplo
Dell 9 PowerEdge R415 Technical Guide Feature SC1435 (predecessor) R410 R415 R610 Embedded HD Controller Chipset-based SATA Chipset-based SATA Chips