Set Extended Configuration Command
6 Data Offset - MSB
7 Bytes to read. FFh means read entire configuration
or attribute
Response Data 1 Completion code
[7:2] - Reserved
[1] - 1b = Set operation in progress
0b = Set complete
[0] - 1b = No more data
2 Configuration ID
3Attribute ID
4 Index (valid only for table object only)
5 Number of bytes returned, 1-based
Depending on the implementation, the number of
bytes returned from BCM might not be the same
as the value of the "Bytes to read" parameter passed
in the request
6:N Data
Byte Data Field
Request Data 1 Reservation ID
2 Configuration ID
3Attribute ID
4 Index (used by table object only)
5 Data Offset to write - LSB
6 Data Offset to write - MSB
Byte Data Field
Page view 62