CONNECTIVITY
This section discusses the different connectivity methods.
Management
EMC has customers that use either the on-array or off-array Navisphere management. Provide
one LAN connection to each Dell/EMC CX Series SP. Use Host Agents to automate connectivity
of hosts at boot time. The agent is not always necessary if a connection was already established,
but it will be needed after a power fail and a restart of the Dell/EMC CX Series. Therefore, it is
recommended to always run the Host Agent.
Protocols
There are two protocols available for Dell/EMC CX Series storage systems: Fibre Channel (FC)
and iSCSI. The FC protocol is available for all CX3 Series systems. Limited CX3 devices allow
iSCSI as an option. Refer to the product listing on http://www.EMC.com for a complete list of CX3
Series systems that support iSCSI.
iSCSI connections
iSCSI connections from the storage system can be made to either network interface cards (NIC)
or TCP/IP offload engines (TOE). Use cat 6 cables to connect to the Dell/EMC CX Series iSCSI
ports.
The Microsoft, QLogic, and Dell/EMC CX Series software all provide ping and trace-route
capability to assist with troubleshooting connections. Use these tools to check connectivity if the
host or the Dell/EMC CX Series report that they do not have a connection.
NIC cards
The NIC port speed can be set to 10/100/1000 Gb with CX3 iSCSI/FC storage systems. Use
IEEE 802.3 certified NIC cards.
TOE cards
Check the EMC Support Matrix for the current list of supported TOE cards. When using a TOE
card, you need to remove the native (Microsoft) iSCSI driver from the host. Booting from SAN
requires a TOE card.
iSCSI security
Currently the only iSCSI security supported is the Challenge Handshake Authentication Protocol
(CHAP). CHAP requires a secret password on both the host and the Dell/EMC CX Series be set
during installation. At a minimum, use initiator-based CHAP security. The secret password must
be 12-to-16 characters long and must be correctly typed on both sides of the connection. Typos
in the secret name will cause the connection to break when CHAP is enabled.
Fibre Channel connections
EMC supports Emulex and QLogic host bus adapters (HBAs). For specific types, firmware
revisions, and driver revisions, refer to the EMC Support Matrix.
Use current drivers and firmware. Current driver and firmware revs for HBAs can be found in the
EMC Support Matrix.