For HBA device driver settings, driver levels, or components in the data path, tape or disk
configurations should include any patches, firmware updates, or configuration settings for each
component in or on the data path.
Emulex HBAs
Use the EMC setting in the HBA configuration utility. Supported Emulex HBAs and driver revs can
be found in the EMC Support Matrix on EMC Powerlink.
Settings for Emulex
Use the settings defined in the Emulex driver installation manual for the specific HBA.
Variations for tape
When using tape, there are two more settings needed:
Use PLOGI instead of PDISC after LIP Always set this when connecting tape devices to the
HBA.
Disable target reset for tape devices – This should be set when using tape devices and VERITAS
cluster software. If cluster software is not used, this parameter should not be set.
QLogic HBAs: QLogic settings
Some HBAs may not come with the EMC settings. If the settings on the HBA match the EMC
settings, then the HBA was preconfigured to the correct settings for connection to a Dell/EMC CX
Series.
Data path
The data path should be redundant to reduce the chance for failures. Multipath software runs on
the attached host. A minimum of two paths—one to each SP—must be created to provide
redundancy. For a complete list with software revisions refer to the EMC Customer Matrix.
EMC recommends using PowerPath
®
for multipath host software for the supported hosts. To take
advantage of PowerPath load balancing and redundancy, create four paths to the Dell/EMC CX
Series. This can be accomplished with two HBAs and two ports per SP.
EMC recommends dual-attached hosts.
Host bus adapters
EMC also recommends persistent binding from the host to the Dell/EMC CX Series.
Recommended HBAs
The most prevalent HBAs in use with and supported by EMC are QLogic and Emulex. Other
native adapters include the Sun adapters (which are QLogic HBAs), and IBM adapters, (which
are Emulex HBAs).
Refer to the EMC Support Matrix for specific HBA and driver support for the hosts in your
environment.
Dell/EMC CX Series SP ports
Use the lower numbered ports for general connectivity.
The highest numbered port is used for MirrorView connections. All ports can be used for other
general connections but it is recommended to keep the high port exclusively for mirroring. If
MirrorView is not installed then the high ports should be used for general connectivity.
Dell/EMC CX Series Initial Configuration
Best Practices Planning 26