10°C to 35°C at 10% to 80% relative humidity (RH), with 26 °C max dew point. De-
rate maximum allowable dry bulb temperature at 1 °C/300m above 900m (1 °F
per 550 ft).
When operating in the expanded temperature range, system performance may be
impacted. When operating in the expanded temperature range, ambient
temperature warnings may be reported on the LCD and in the System Event Log.
≤10% of annual operating hours: 5°C to 40°C at 5% to 85% RH with 26°C dew
point.
≤1% of annual operating hours: –5°C to 45°C at 5% to 90% RH with 26°C dew
point.
Outside the standard operating temperature (10 °C to 35 °C), the system can
operate down to 5 °C or up to 40 °C for a maximum of 10% of its annual
operating hours. For temperatures between 35 °C and 40 °C, de-rate maximum
allowable dry bulb temperature by 1 °C per 175 m above 950 m (1 °F per 319 ft).
Outside the standard operating temperature (10 °C to 35 °C), the system can
operate down to –5 °C or up to 45 °C for a maximum of 1% of its annual
operating hours.
For temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb
temperature by 1 °C per 125 m above 950 m (1 °F per 228 ft).