Dell TL1000 User's Guide Page 141

  • Download
  • Add to my manuals
  • Print
  • Page
    / 194
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 140
Table A-1. Library error codes (continued)
Code (H) Description Panel Indication Action Required
00DD
An error detected during bar code
reader firmware check. Suspect
the bar code reader cable
connection.
CHK 00DD
1. Initiate an inventory. See “Conducting a
library inventory” on page 4-7 (Operator
Panel) or “Conducting a library inventory”
on page 4-22 (Web User Interface).
2. Cycle the power supply and try again.
v If the problem is corrected, run Library
Verify before normal library operations
resume.
v If the problem persists, see “Contacting
Dell technical support” on page 7-2.
00E0
Write operation not finished
within 1 ms when writing data to
flash memory.
CHK 00E0
Cycle the power supply and try again.
v If the problem is corrected, run Library Verify
before normal library operations resume.
v If the problem persists, see “Contacting Dell
technical support” on page 7-2.
00E1
Clear operation not finished
within 10 seconds when clearing a
sector in flash memory.
CHK 00E1
00E2
Error detected in tape library
configuration stored in flash
memory.
CHK 00E2
00E3
Checksum error detected in flash
memory.
CHK 00E3
00F0
Sensor error #1.
Accessor encoder sensor B error
detected during blink check.
Suspect the accessor encoder
sensor B.
CHK 00F0
Appendix A. Error codes A-9
Page view 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 193 194

Comments to this Manuals

No comments