Dell PowerEdge 2650 User Manual

Browse online or download User Manual for Servers Dell PowerEdge 2650. Dell PowerEdge 2650 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 43
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Dell™PowerEdge™2650SystemsUser'sGuide
System Overview
Using the Dell OpenManage Server Assistant CD
Using the System Setup Program
Technical Specifications
I/O Ports and Connectors
Installing and Configuring SCSI Drivers
Using Console Redirection
Glossary
Notes, Notices, and Cautions
Information in this document is subject to change without notice.
©2001DellComputerCorporation.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerEdge, and Dell OpenManage are trademarks of Dell Computer Corporation; Intel is a registered trademark and Intel386 and
Xeon are trademarks of Intel Corporation; Microsoft, MS-DOS, Windows NT, and Windows are registered trademarks of Microsoft Corporation; Novell and NetWare are registered
trademarks of Novell, Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Computer Corporation
disclaims any proprietary interest in trademarks and trade names other than its own.
Model SMP01
Initial release: 18 Dec 01
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Page view 0
1 2 3 4 5 6 ... 42 43

Summary of Contents

Page 1 - Notes, Notices, and Cautions

Dell™PowerEdge™2650SystemsUser'sGuide System Overview Using the Dell OpenManage Server Assistant CD Using the System Setup Program Technica

Page 2 - Technical Specifications

SCSI Bus Interface Definitions The basic host adapter settings are the SCSISelect settings most likely to require modification: l Host Adapter SCSI I

Page 3

boot your system. When this option is set to No, the devices are allowed to start at the same time. Most devices require you to set a jumper before th

Page 4 - I/O Ports and Connectors

l Format Disk — Runs a utility that allows you to perform a low-level format on a hard drive. Most SCSI disk drives are formatted at the factory and d

Page 5 - Keyboard Connector

Back to Contents Page Using Console Redirection Dell™PowerEdge™2650SystemsUser'sGuide Minimum Hardware and Connection Requirements So

Page 6 - Mouse Connector

Configuring Console Redirection on the Client System Configuring the Ports 1. Click the Start button, point to Programs—> Accessories—> Commun

Page 7 - USB Connectors

For console redirection, an escape sequence starts with an escape character. This character can be entered in a number of different ways, depending on

Page 8 - Integrated NIC Connectors

After you create these macros, pressing <F1> on the keyboard while running the terminal emulation software sends <Esc><Shift>op to t

Page 9 - The SCSISelect Utility

Back to Contents Page System Overview Dell™PowerEdge™2650SystemsUser'sGuide System Status Indicators System Identification Indicators

Page 10 - Boot Device Options

System Identification Indicators You can use identification buttons on the front and back panels to locate a particular system within a rack. When you

Page 11

Power Indicator The system has indicators on the front panel and the power supplies that denote system power status (see Figure1-2). Power Indicator

Page 12 - Exiting SCSISelect

Back to Contents Page Technical Specifications Dell™PowerEdge™2650SystemsUser'sGuide Microprocessor Expansion Bus Memory Drives 

Page 13 - Using Console Redirection

l White characters on a blue background — Information only; no action is required. l Amber character on a black background — The system needs attenti

Page 14 - Configuring Special Keys

NIC Indicators Each NIC on the back panel has an indicator that provides information on network activity and link status (see Figure1-6). Table1

Page 15 - EscapeSequences

l Up to two hot-pluggable, 500-W power supplies in a 1 + 1 redundant configuration. l Hot-pluggable system cooling fans and two additional fans integ

Page 16

system for a limited amount of time—from 15 minutes to an hour or so—depending on the UPS system. UPS systems that provide only 5 minutes of battery

Page 17 - System Overview

Back to Contents Page Using the Dell OpenManage Server Assistant CD Dell™PowerEdge™2650SystemsUser'sGuide StartingtheDellOpenManage

Page 18 - Front-Panel Features

Utility Partition The utility partition is a bootable partition on the hard drive that contains system configuration and diagnostic utilities. When im

Page 19 - Status LCD

4. When you are prompted to verify the asset tag number, type y and press <Enter>. The system then displays the new or modified asset tag num

Page 20 - Back-Panel Features

Back to Contents Page Using the System Setup Program Dell™PowerEdge™2650SystemsUser'sGuide Entering the System Setup Program System S

Page 21 - System Features

System Setup Options The following subsections outline the options on the System Setup screens. Main Screen When the System Setup program runs, the m

Page 22 - Power Protection Devices

¡ Front-Panel LCD Options — Selecting this field allows you to select whether you display the service tag, asset tag, or a user-defined string in the

Page 23 - Other Documents You May Need

Back to Contents Page    USB one 4-pin connector PS/2-style keyboard/mouse 6-pin mini-DIN, keyboard default (mouse optional with combination Y

Page 24 - Setting Up Your System

l Power Button — When this option is set to Enabled,youcanusethepowerbuttontoturnthesystemofforshutdownthesystemifyouarerunningMi

Page 25 - Asset Tag Utility

4. Press <Enter>. 5. To confirm your password, type it a second time and press <Enter>. The System Password option changes to Enable

Page 26

Assigning a Setup Password A setup password can be assigned (or changed) only when the Setup Password option is set to Not Enabled. To assign a setup

Page 27

Back to Contents Page Glossary Dell™PowerEdge™2650SystemsUser'sGuide The following list defines or identifies technical terms, abbreviat

Page 28 - System Setup Options

You can start your system from a bootable diskette. To make a bootable diskette, insert a diskette in the diskette drive, type sys a: at the command l

Page 29 - System Security Screen

diagnostics A comprehensive set of tests for your system. Refer to your Installation and Troubleshooting Guide for more information about using diagno

Page 30 - Assigning a System Password

extended memory RAM above 1 MB. Most software that can use it, such as the Microsoft®Windows®operating system, requires that extended memory be unde

Page 31

IDE Abbreviation for integrated drive electronics I/O Abbreviation for input/output. A keyboard is an input device, and a printer is an output device.

Page 32 - Assigning a Setup Password

lb Abbreviation for pound(s). LED Abbreviation for light-emitting diode. An electronic device that lights up when a current is passed through it. loca

Page 33 - Glossary

A pointing device that controls the movement of the cursor on a screen. Mouse-aware software allows you to activate commands by clicking a mouse butto

Page 34

Back to Contents Page I/O Ports and Connectors Dell™PowerEdge™2650SystemsUser'sGuide Serial Ports Keyboard and Mouse Connectors Vid

Page 35

protected mode An operating mode supported by 80286 or higher microprocessors, protected mode allows operating systems to implement: l A memory addres

Page 36

SEC Abbreviation for single-edge contact. serial port An I/O port used most often to connect a modem to your system. You can usually identify a serial

Page 37

A start-up file for the Windows operating system. When you start Windows, it consults the system.ini file to determine a variety of options for the Wi

Page 38

The logical circuitry that provides—in combination with the monitor—your system's video capabilities. A video adapter may support more or fewer f

Page 39

 Adding an Expansion Card Containing Serial or Parallel Ports The system has an autoconfiguration capability for the serial ports. This feature le

Page 40

If you reconfigure your hardware, you may need pin number and signal information for the keyboard connector. FigureB-4 illustrates the pin numbers fo

Page 41

Video Connectors The system uses a 15-pin high-density D-subminiature connector on the front and back panels for attaching a VGA-compatible monitor to

Page 42

Integrated NIC Connectors Your system has two integrated 10/100/1000–Mbps NICs. The 10/100/1000-Mbps NICs provide faster communication between server

Page 43

Back to Contents Page Installing and Configuring SCSI Drivers Dell™PowerEdge™2650SystemsUser'sGuide The SCSISelect Utility This sectio

Comments to this Manuals

No comments