2111 Failure prediction
threshold exceeded
due to test - No
action needed
Warning /
Non-critical
Cause: A disk has received a SMART alert
(predictive failure) due to test conditions.
Action: None
903 590
2112 Enclosure was shut
down
Critical /
Failure /
Error
Cause: The array disk enclosure is either
hotter or cooler than the maximum or
minimum allowable temperature range.
Action: Check for factors that may cause
overheating or excessive cooling. For
example, verify that the enclosure fan is
working. You should also check the
thermostat settings and examine whether the
enclosure is located near a heat source. Make
sure the enclosure has enough ventilation and
that the room temperature is not too hot or
too cold. See the enclosure documentation
for more diagnostic information.
854 602
2114 A consistency check
on a virtual disk has
been paused
(suspended)
Ok /
Normal
Cause: The check consistency operation on a
virtual disk was paused by a user.
Action: To resume the check consistency
operation, right-click the virtual disk in the
Storage Management tree view and select
Resume Check Consistency.
1201 604
2115 A consistency check
on a virtual disk has
been resumed
Ok /
Normal
Cause: The check consistency operation on a
virtual disk has resumed processing after
being paused by a user.
Action: This alert is provided for
informational purposes.