Dell OpenManage Server Administrator Version 2.3 User's Guide Page 89

  • Download
  • Add to my manuals
  • Print
  • Page
    / 106
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 88
Storage Management Message Reference 91
2329 SAS port report: %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Warning /
Non-critical
Cause: The text for this alert is generated by
the controller and can vary depending on
the situation.
Action: Make sure the cables are attached
securely.
If the problem persists, replace the cable with
a valid cable according to SAS specifications.
If the problem still persists, you may need to
replace some devices such as the controller or
EMM. See the hardware documentation for
more information.
753 None
2330 SAS port report: %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
751 None
2331 A bad disk block has
been reassigned.
Warning /
Non-critical
Cause: The disk has a bad block. Data has
been readdressed to another disk block and
no data loss has occurred.
Action: Monitor the disk for other alerts or
indications of poor health. For example, you
may receive alert 2306. Replace the disk if
you suspect there is a problem.
903 None
2332 A controller hot plug
has been detected.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
751 None
2333 An enclosure
temperature sensor
differential has been
detected.
Warning /
Non-critical
Cause: The firmware has detected a
temperature sensor differential in the
enclosure.
Action: Monitor the enclosure for other alerts
related to the temperature. For example, you
may receive alerts related to the fan or
temperature probes. Check the health of the
enclosure and its components. Replace any
component that is failed.
853 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number
Page view 88