Dell PowerEdge 1850 Technical Information Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
Information Update 1-7
6
Reconnect the system to the electrical outlet, and turn on the system and attached
peripherals.
If there is no memory-related error message, the problem is resolved.
If the problem persists, see "Getting Help" in your
Installation and Troubleshooting Guide
.
There are memory-related error messages in the SEL.
1
Enter the System Setup program and disable the
Redundant Memory
option, if applicable.
See "Using the System Setup Program" in your
User's Guide
.
2
Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics"
in your
Installation and Troubleshooting Guide
.
3
Replace the memory module(s) identified by the diagnostics. See "Installing Memory
Modules" in your
Installation and Troubleshooting Guide
.
4
Enter the System Setup program and enable the
Redundant Memory
option, if disabled
in step 1.
5
Restart the system. If there are still memory-related errors in the SEL, see "Getting Help"
in your
Installation and Troubleshooting Guide
.
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 57 58

Comments to this Manuals

No comments