Dell PowerVault 56F (16P Fibre Channel Switch) User Manual Page 1

Browse online or download User Manual for Computer hardware Dell PowerVault 56F (16P Fibre Channel Switch). Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 172
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0





Page view 0
1 2 3 4 5 6 ... 171 172

Summary of Contents

Page 1 - 



Page 2

xii When transporting a sensitive component, first place it in an antistatic container or packaging. Handle all sensitive components in a static-saf

Page 3 - 

5-2 Installation and Troubleshooting GuideTo retest a port which has been marked ;03, clear the port and set to %Kusing the diagClearError <

Page 4 - 

support.dell.com Troubleshooting 5-3. 6&)The color and flash speed of each port’s LED, as described in Table 5-2, indica

Page 5

5-4 Installation and Troubleshooting Guide7. Fabric analysis; the switch checks for ports connected to other fabric elements. If there are other fabri

Page 6

support.dell.com Troubleshooting 5-5%1) 

Page 7

5-6 Installation and Troubleshooting Guide%&Pressing <Enter> while the Port Register Test window is selected displays a remi

Page 8

support.dell.com Troubleshooting 5-7 (&The camTest verifies that the SID translation required by QuickLoop and implemented using content addr

Page 9

5-8 Installation and Troubleshooting Guide-NOTE: All ports on the switch must be connected or else the

Page 10 -  !

support.dell.com Troubleshooting 5-9not sent, the switch does not know the port is connected to another port on the same switch and the test fails.An

Page 11 - 4 Feet flat on the floor

5-10 Installation and Troubleshooting Guide

Page 12

support.dell.com Repair and Replacement 6-1$ #$ "This chapter covers the recommended and supported field repair and repl

Page 13 - !"#

xiii1 Monitor screen at or below eye level2 Wrists relaxed and flat3 Arms at desk level4 Feet flat on the floor5 Monitor and keyboard positioned direc

Page 14

6-2 Installation and Troubleshooting Guide#%%To remove the power supply, you must perform the following steps. $

Page 15

support.dell.com Repair and Replacement 6-3$#0&GBIC modules are installed and removed by inserting them into the system board f

Page 16

6-4 Installation and Troubleshooting Guide$-!Replacing the fan assembly involves removing the the existing fan assembly, and i

Page 17 - 

support.dell.com Repair and Replacement 6-5)"#.!1. Inset the new fan assembly into the switch’s front assembly cavity.2.

Page 18

6-6 Installation and Troubleshooting Guide-!, !#')81. Insert the system board module into

Page 19

support.dell.com Repair and Replacement 6-70;,*<

Page 20

6-8 Installation and Troubleshooting Guide

Page 21

support.dell.com Getting Help 7-1%& This chapter describes the tools Dell provides to help you when you have a problem with your

Page 22 - 

7-2 Installation and Troubleshooting Guide "Dell provides a number of tools to assist you. These tools are described in the follow-ing se

Page 23

support.dell.com Getting Help 7-3!Dell’s automated technical support service—AutoTech—provides recorded answers to the questions most f

Page 25 - 

7-4 Installation and Troubleshooting Guide!%If you have a problem with your order, such as missing parts, wrong parts, or in

Page 26 - /

support.dell.com Getting Help 7-50NOTE: Have your Express Service Code ready when you call. The code helps Dell’s automated-support tele

Page 27 -  

7-6 Installation and Troubleshooting Guide&'/9Name: ______________________________________

Page 28

support.dell.com Getting Help 7-7!When you need to contact Dell, use the telephone numbers, codes, and electronic addr

Page 29 - 

7-8 Installation and Troubleshooting Guide/.'!#)  Aus

Page 30

support.dell.com Getting Help 7-9/5!Spain (Madrid) 07 34 91Sweden (Upplands Vasby) 009 46 8Switzerland (Geneva) 00 41 22T

Page 31 -  

7-10 Installation and Troubleshooting GuideBelgium(Brussels)Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . .

Page 32 - 7

support.dell.com Getting Help 7-11China(Xiamen)Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 800 858

Page 33 - -!"

7-12 Installation and Troubleshooting GuideFrance(Paris/Montpellier)Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . 0803 . . . . .

Page 34 - ##%%

support.dell.com Getting Help 7-13Ireland(Bray)Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-85

Page 35 - 

xv!"#This guide is intended for anyone who is installing and managing a Dell PowerVault 56F 16-Port Fibre Channel switch. It

Page 36 - &'

7-14 Installation and Troubleshooting GuideKorea(Seoul)Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free:

Page 37 - '8

support.dell.com Getting Help 7-15Mexico(Colonia Granada)NOTE: Customers in Mexico call the U.S.A. for access to the Automated Order-Status Sys-tem an

Page 38 - !&%

7-16 Installation and Troubleshooting GuidePoland(Warsaw)Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . 22 . . . . . . . . .

Page 39

support.dell.com Getting Help 7-17Spain(Madrid)Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Page 40 - '

7-18 Installation and Troubleshooting GuideU.K.(Bracknell)Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 41

support.dell.com Getting Help 7-19U.S.A.(Austin, Texas)Automated Order-Status System . . . . . . . . . . . . . . . . . . . . .toll free: 1-800-433-901

Page 42 - '

7-20 Installation and Troubleshooting Guide

Page 43 - $

support.dell.com Error Messages A-1'!This appendix explains the error message format, error message by firmware module, and

Page 44 - $#$&'

A-2 Installation and Troubleshooting Guide0!!'+4!To display error messages by way of Te l n e t :1. From the prompt,

Page 45 - ' 

support.dell.com Error Messages A-3INPORT (2) The input port in the IU received by the path selection task is out of range.Check that all paths and ro

Page 46 - ' 

xvi$Dell Computer Corporation (“Dell”) manufactures its hardware products from parts and components that are new

Page 47

A-4 Installation and Troubleshooting GuideREMPORT (3) Removing an entry from a multi-cast routing table failed.Run the portLogShow command. Con-tact C

Page 48 - (

support.dell.com Error Messages A-56This module includes errors that cause a system panic to occur. A system panic causes the switch to reb

Page 49

A-6 Installation and Troubleshooting Guide;;)66The software includes several message queues that are used for inter-task communi-cation. Eac

Page 50

support.dell.com Error Messages A-7For information on executing these commands, contact Dell for technical assistance.%!This sectio

Page 51 - '#

A-8 Installation and Troubleshooting Guide6Table A-5 shows the port error messages:0+&> &

Page 52 - &

support.dell.com Error Messages A-96Table A-6 show the thermometer error message.NOTE: Error messages are stored in volatile

Page 53

A-10 Installation and Troubleshooting GuideThe possible security level values are: 1 — Critical 2 — Error 3 — Warning 4 — Informational 5 — Debug

Page 54

support.dell.com Error Messages A-11(,An error number (//T++++appears at the end of an error message. Table A-9 matches each error

Page 55

A-12 Installation and Troubleshooting Guide1020 centralMemoryTest DIAG-CMBISRTO1021 DIAG-CMBISRF1025 DIAG- LCMRS1026 DIAG- LCMTO1027 DIAG- LCMEM1028 D

Page 56 - #

support.dell.com Error Messages A-13264F DIAG-INIT265F DIAG-PORT_DIED266E DIAG-DATA266F DIAG-TIMEOUT2660 DIAG-STATS(FTX)2661 DIAG-STATS(FRX)2662 DIAG-

Page 57

xviiSyntax lines consist of a command and all its possible parameters. Commands are displayed in lowercase bold; variable parameters (those for which

Page 58 - &

A-14 Installation and Troubleshooting Guide6Table A-9 matches each error number with the test that caused the error and the name of

Page 59 - % 

support.dell.com Error Messages A-15DIAG-BUS_TIMEOUT(T;%)5)[portRegTest, sramRetention-Te s t ]ASIC register or ASIC SRAM did not respond to a

Page 60

A-16 Installation and Troubleshooting GuideDIAG-CMINOCAP(T!--[cmiTest]CMI intended receiver ASIC failed to get CMI capture flagASIC or mainboard fa

Page 61 - #

support.dell.com Error Messages A-17DIAG-INTNOTCLR(T!"[centralMemoryTest]The interrupt bit could not be clearedASIC failure Replace main-boar

Page 62 - 

A-18 Installation and Troubleshooting GuideDIAG-POST_SKIPPED(T[switch initialization]POST is skipped; its message recommended that POST be execu

Page 63

support.dell.com Error Messages A-19FABRIC, SEGMENTED, LOG_WARNINGFabric segmented Incompatible fab-ric parameters/switchesConflict zonesContact custo

Page 64

A-20 Installation and Troubleshooting GuidePOWER, 1_FAILED, LOG_CRITICALSwitch Power Failure Power supply fail-ureContact customer supportPOWER, 2_FAI

Page 65 - % $  

support.dell.com Error Messages A-21PANIC, MALLOC, LOG_PANIC Memory allocation failed OS error Contact customer supportPANIC, FREE, LOG_PANIC Memory f

Page 66 - (!

A-22 Installation and Troubleshooting GuideASIC, MINI_BUFFER, LOG_WARNINGASIC failure OS error Contact customer supportLSDB, LSID, LOG_ERROR Link Stat

Page 67 - %  

support.dell.com Error Messages A-23MCAST, ADDPORT, LOG_WARNINGAdd port failed OS error Contact customer supportMCAST, REMPORT, LOG_WARNINGRemove port

Page 68

xviii

Page 70

support.dell.com Glossary 1%The following list defines or identifies technical terms, abbreviations, and acro-nyms used in Del™l user documents

Page 71 - &%

2 Installation and Troubleshooting Guide%The domain number uniquely identifies the switch in a fabric. This switch domain ID is normally autom

Page 72

support.dell.com Glossary 3A loop is a configuration of devices (for example, JBODs) connected to the fabric via an FL_Port interface card.1

Page 73

4 Installation and Troubleshooting Guideswitches that make up the fabric. This is for a single copy of the data to be sent to designated destinations.

Page 74 -  The alias token

support.dell.com Index 1#(ADDBRANCH (2), A-3ADDPATH (1), A-4ADDPORT (3), A-3agtcfgSet command, 4-4agtcfgShow command, 4-5aliasShow command, 4-5arb

Page 75

2 Installation and Troubleshooting Guidecommands (continued)errDump, 4-15fabricShow, 4-17firmwareDownload, 4-18flashDefault, 4-18flashSet, 3-10fspfSho

Page 76 -  Licensed

support.dell.com Index 3errorsADDBRANCH (2), A-3ADDPATH (1), A-4ADDPORT(3), A-3BADSRC (3), A-2diagnostic formats, A-10ENQFAIL (1), A-4failure actions,

Page 77 - %!

4 Installation and Troubleshooting Guidei command, 4-20ifShow command, 4-21INCONSISTENT (0), A-5initialization, 5-3INPORT (2), A-3installationGBIC mo

Page 78

support.dell.com Index 5passwd command, 4-23passwordschanging, 3-17portdisable, 3-13enable, 3-13throughput, 3-16portDisable command, 4-24portEnable c

Page 79

xix'%( )&*#+*,-.(-.'# /////////////////////////

Page 80 - %6#

6 Installation and Troubleshooting Guidestatus menu, 3-14subnet mask, 3-8supporttechnical, 7-1swFault, 3-20swFCPortScn, 3-20switchDisable command, 4-2

Page 81 - %#

support.dell.com Index 7warmStart, 3-20warnings, vwarranty information, xviwarranty repair or credit, 7-4World Wide Web help tools, 7-26ZOMTIMKILL (0

Page 82

8 Installation and Troubleshooting Guide

Page 83 -  

xx'%1 #+,-.(-.'# ///////////////////1(Compatibility With PowerVault 5

Page 84 - #"

xxiManage Node Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20Name Server . . . . . . . . . . . . . . .

Page 85 - ##

____________________Information in this document is subject to change without notice.© 2000 Dell Computer Corporation. All rights reserved.Reproductio

Page 86

xxiiswitchDisable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28switchEnable . . . . . . . . .

Page 87

xxiiiCMI Conn Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6CAM Test . . . . . . . . . . . . . .

Page 88

xxivBefore You Call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5Diagnostics Checklist.

Page 89 - $

xxvFigure A-1. errShow Command Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2Figure A-2. MQ-QWRITE Error Example . . . . .

Page 90 - %#

xxviTable A-5. Port Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8Table A-6. Thermometer Error Message

Page 91 - #

support.dell.com Installing the Dell PowerVault 56F 16-Port Fibre Channel Switch 1-1

Page 92 - 

1-2 Installation and Troubleshooting Guide)$.Switch power connection is by way of a switched connector on the switch’s front right sid

Page 93 - 

support.dell.com Installing the Dell PowerVault 56F 16-Port Fibre Channel Switch 1-3#0&)%Each switch supports six

Page 94 - &#

1-4 Installation and Troubleshooting GuideVarious lengths of copper and shortwave optical cables are available from Dell. These cables have been desig

Page 95 - #

support.dell.com Installing the Dell PowerVault 56F 16-Port Fibre Channel Switch 1-5-You can use the front panel controls for initi

Page 96 - %#

vUse the following safety guidelines to ensure your own personal safety and to help protect your computer or storage system from po

Page 97 - 

1-6 Installation and Troubleshooting Guide

Page 98 - #

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Topologies 2-1 This chapter

Page 99 - 

2-2 Installation and Troubleshooting Guideinformation regarding the cost of the shortest path to another switch from which you can derive the number o

Page 100 - #

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Topologies 2-3fabric-attached devices communicate, the FL_Port automatically translates b

Page 101 - ):%

2-4 Installation and Troubleshooting GuideEach connection is full duplex with transmissions up to 1 Gbps simultaneously, in both directions, between t

Page 102 - "

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-1!This chap

Page 103 - 

3-2 Installation and Troubleshooting Guide)&&Before changing any of the factory default settings, become famil

Page 104 - ( &

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-3$&!&'&"

Page 105 - &

3-4 Installation and Troubleshooting GuideWhen entering a number, the <Up> and <Down> buttons start in the slow mode and change to the fas

Page 106 - &

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-5$$&'&Configuration Menu 

Page 107 - &

vi$%&11"

Page 108

3-6 Installation and Troubleshooting Guide'Table 3-4 shows the front panel commands and their equivalent Te l n e t command.$(

Page 109 - $ #$ "

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-7Worldwide name switchShow N/AFirmware Version version N/ACurrent Date dat

Page 110 - )#%%

3-8 Installation and Troubleshooting Guide'Configure the switch using the Configuration Menu. Pressing <Enter> while in th

Page 111 - $#0&

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-9 4,To enter an IP address, perform the

Page 112 - $-!

3-10 Installation and Troubleshooting GuideThe number displayed represents the number of buffers, from 1 to 16, available to the host. For a complete

Page 113 - 8

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-11(The operating modes are determined by the host adapter. Th

Page 114 - $

3-12 Installation and Troubleshooting Guide'  Pressing <Enter> while VC Link Ctl is selected displays the virtual channel link con-

Page 115

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-13 Pressing <Enter> while Frame Collection is selecte

Page 116

3-14 Installation and Troubleshooting GuideRebooting the switch causes it to immediately exit all current processes and states, and start the POST pro

Page 117 - %&

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-154*Pressing <Enter> while Flash Date is selected displays t

Page 118 - "

vii If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact your Dell authorized serv

Page 119 - %%

3-16 Installation and Troubleshooting GuideC — copper,Pressing <Enter> while Port Throughput is selected displays the port throug

Page 120 - 

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-17>The tests available from the Test Menu are part of the diagn

Page 121 - 0

3-18 Installation and Troubleshooting Guide3. Each username (admin, user, other) is displayed in sequence, allowing the admin-istrator to modify each

Page 122

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-19MIB-II system group, interface group, and SNMP group

Page 123

3-20 Installation and Troubleshooting Guide%Setting up the switch’s SNMP connection to an existing managed network allows the network syst

Page 124 - 

support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-21The configurable parameters include the following:SNMPv1 communities (u

Page 125

3-22 Installation and Troubleshooting GuideCommon Transport (CT) requests and responses including Name Server are recorded in the portLog. A typical t

Page 126 - ) (

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-1""#This c

Page 127

4-2 Installation and Troubleshooting Guide&This agtcfgDefault command allows admin to reset the configuration of the Simple Network M

Page 128

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-3#9'4444'4"'4

Page 129

viiiadapter plugs or remove the grounding prong from a cable. If you must use an extension cable, use a three-wire cable with properly grounded plugs.

Page 130

4-4 Installation and Troubleshooting GuideIn addition, six communities and respective trap recipients are supported by the agent. The first three comm

Page 131

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-5#The agtcfgShow command displays current SNMP agent configuration. T

Page 132

4-6 Installation and Troubleshooting GuideFigure 4-1, Figure 4-2, and Figure 4-3 show examples of the configure command, which is used to set

Page 133

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-7entered at the prompt, as shown in Figure 4-1. The various configuration sett

Page 134

4-8 Installation and Troubleshooting Guide.(%!!'!switch:admin> configureConfigure...Fabric parameters (yes, y

Page 135

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-9($%!!'#,"%-.

Page 136

4-10 Installation and Troubleshooting GuideA listing of the configurable fabric parameters is shown in Table 4-5.(!% 

Page 137 - '!

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-11The switch provides the ability to tune the switch in a specific application

Page 138 - "

4-12 Installation and Troubleshooting GuideTable 4-7 describes the arbitrated loop parameters.VC Class 3 Sets the virtual channel used for Class 3 fra

Page 139

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-13Table 4-8 describes the system services.(1 !,% 

Page 140

ix Move products with care; ensure that all casters and/or stabilizers are firmly con-nected to the computer or storage system. Avoid sudden stops an

Page 141 - 6

4-14 Installation and Troubleshooting Guide&The configDefault command is used to reset some of the switch configuration values to thei

Page 142 -  The message pointer (

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-15d.MM are the minutese.yy is the year2. Press <Enter> to set the date a

Page 143 - %!

4-16 Installation and Troubleshooting Guide#The errShow command displays all detected errors, one error at a time. The error log stores the last

Page 144 - 6

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-17#The fabricShow command displays a list of switches and multicast a

Page 145 - ..

4-18 Installation and Troubleshooting GuideThe fastboot command initiates a warm reboot that bypasses POST and takes about one minute to reboo

Page 146 - %$ )

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-193. In the program list, click Dell OpenManage PowerVault Manager, then click

Page 147 - (,

4-20 Installation and Troubleshooting GuideThe help display changes depending on the login user level, license key, and switch model, and will display

Page 148

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-21#The ifShow command displays a summary of currently running tasks. The

Page 149

4-22 Installation and Troubleshooting GuideAfter each prompt, the current value is shown inside brackets; the user may enter one of the following acti

Page 150 - 6

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-23#The nsShow command displays local name server information, which inclu

Page 151

x Ensure that proper airflow is provided to components in the rack. Do not step on or stand on any system/component when servicing other sys-tems/co

Page 152

4-24 Installation and Troubleshooting GuideThe optional parameter B'48 is a double-quoted, valid user name.If the current password is inco

Page 153

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-25% 'The portLogClear command clears the data from the port log.

Page 154

4-26 Installation and Troubleshooting Guide(!!''% stat_wtx Number of 4-byte

Page 155

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-27%#The following example shows the psShow command screen, which displays

Page 156

4-28 Installation and Troubleshooting GuideThe reboot command reboots the switch to the stored configuration in flash memory and takes about 1 1

Page 157

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-29Certain restrictions apply to the length and format of the switch name. Spec

Page 158

4-30 Installation and Troubleshooting Guide(/!!''% switchName The switch nameswit

Page 159

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-31)%The syslogdIp command sets or displays the switches system log daem

Page 160

4-32 Installation and Troubleshooting Guide%The uptime command can be used to display the amount of time the switch has been in operation (also k

Page 161 - %

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-33/License commands are reserved for use by Dell only.$

Page 162

xi":)

Page 163

4-34 Installation and Troubleshooting Guide%#The following example shows the fspfShow command screen, which displays Fibre Channel Shortest Path

Page 164

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-35 #The interfaceShow command displays FSPF interface information.

Page 165

4-36 Installation and Troubleshooting GuidelastUpTime Last time this interface came up.downCount Number of times this interface went downlastDownTime

Page 166

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-37The iodReset command turns off the in-order delivery option. This co

Page 167

4-38 Installation and Troubleshooting Guide &#The LSDbShow command displays domain Link State Database entries. The data-base record for any

Page 168

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-39#The mcastShow command, without parameters, displays multicast tree

Page 169

4-40 Installation and Troubleshooting Guide4%The following example shows the routeHelp command screen, which displays the routing help commands

Page 170

support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-41The following is an example of the topologyShow command screen.'

Page 171

4-42 Installation and Troubleshooting Guide#Table 4-25 shows the uRouteShow command, which displays the port's unicast rout-ing informat

Page 172

support.dell.com Troubleshooting 5-1This chapter discusses troubleshooting, diagnostic testing, and error messages, including

Comments to this Manuals

No comments