Dell PowerEdge M605 User Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 201
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
20 Getting Started With Your System
Fibre Channel Pass-Through Module
Externally accessible connectors
Fibre Channel transceiver
Sixteen external SFP ports that support
1/2/4-Gbps FC speeds
Brocade Fibre Channel Switch Module
Externally accessible connectors
Fibre Channel
Eight physical FC ports (four enabled by
default, upgradeable to eight) supporting
1/2/4-Gbps Fibre Channel connections
Serial Port
RJ-45
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see dell.com/environmental_datasheets. The system is not for
use in an office environment.
Temperature
Operating
10° to 35°C (50° to 95°F)
NOTE: Decrease the maximum
temperature by 1°C (1.8°F) per 300 m (985 ft)
above 900 m (2955 ft).
Storage
–40° to 65°C (–40° to 149°F)
Relative humidity
Operating
8% to 85% (noncondensing) with a
maximum humidity gradation of 10% per
hour
Storage
5% to 95% (noncondensing)
Maximum vibration
Operating
0.26 Grms at 10–350 Hz for 15 min
Storage
1.54 Grms at 10–250 Hz for 15 min
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 200 201

Comments to this Manuals

No comments