22 |Installation Dell PowerConnect W-7200 Series Controller | Installation Guide
Modules must be kept in anti-static packaging when not installed in the chassis.
Do not ship/store this product near strong electro-magnetic, electrostatic, magnetic or radioactive fields.
Do not disassemble the chassis or any module.
Selecting a Location
The W-7200 controller, like other network and computing devices, requires an “electronics friendly”
environment.
Reliable power. Verify that your electrical outlet is compatible with the W-7200 power supplies.
Cool, non-condensing ventilation
For proper operation, the W-7200 requires an environment with an ambient air temperature between 0 and
40 ºC (32 to 104 ºF). Humidity must be kept at non-condensing levels between 5 and 95%.
Where a large number of electrical devices are working in the same area, additional air conditioning or air
circulation equipment may be required.
Ample space
For proper air circulation, leave at least 10 cm (4 inches) clearance for the vents on the left, right, front, and
rear of the chassis.
Leave additional space in front of the chassis to access power cords, network cables, and indicator LEDs.
Limited electromagnetic interference
For best operation, keep the W-7200 controller and all cords and cables at least 0.7 meters (2 feet) from
fluorescent lighting fixtures, and 2 meters (6 feet) from photocopiers, radio transmitters, electric generators,
and other sources of strong electromagnetic interference.
Two-Point Rack Mounting
The included two-point rack mounting kit provides the necessary hardware to securely mount a W-7200
controller in standard 19” telco rack.
Required Tools and Equipment
The following tools and equipment are required for installation of a W-7200 controller:
Rack mount bracket (x2, not used for tabletop installation)
M4 x 6mm Phillips flat head screws (8x, included with rack mount brackets)
M6 x 15mm Phillips flat head screws (4x, 19-inch (48.26 cm) rack system mount screws)
Suitable screwdrivers for both screw types
Installation Steps
To install a W-7200 controller into a two-point 19-inch (48.26 cm) rack system:
1. Place a rack mount bracket over the mounting holes on one side of the controller (see Figure 10).
2. Secure the bracket to the controller using four M4 x 6mm phillips flat head screws and a suitable screwdriver.
CAUTION: Each W-7200 controller should have its own mounting equipment. Do not place other networking equipment directly
on top a mounted W-7200 controller. Failure to do so can result in damage to the device.
NOTE: Some racks require screws that differ from those included with the W-7200 controller. Confirm that you have the correct
screws before installing your W-7200 controller.