24 About Your System
Power cycle—Turn off the system and disconnect it from the electrical
outlet, wait for approximately ten seconds, reconnect the power cable, and
restart the system.
NOTE: The following LCD status messages are displayed in the Simple format. See
"Setup Menu" on page 16 to select the format in which the messages are displayed.
Table 1-1. LCD Status Messages
Code Text Cause Corrective Actions
E1000 Failsafe
voltage
error.
Contact
support.
Check the system event log
for critical failure events.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 189.
E1114 Ambient Temp
exceeds
allowed
range.
Ambient temperature has a
reached a point outside of
the allowed range.
See "Troubleshooting
System Cooling
Problems" on page 161.
E1116 Memory
disabled,
temp above
range. Power
cycle AC.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems" on page 161. If
the problem persists, see
"Getting Help" on
page 189.
E1210 Motherboard
battery
failure.
Check
battery.
CMOS battery is missing or
the voltage is outside of the
allowable range.
See "Troubleshooting the
System Battery" on
page 160.