144 omconfig: Managing Components Using the Instrumentation Service
Example Shutdown Commands
To set the shutdown action to reboot, type:
omconfig system shutdown action=reboot
or
omconfig servermodule shutdown action=reboot
To bypass operating system shutdown before the system is powered off, type:
omconfig system shutdown action=reboot osfirst=
false
or
omconfig servermodule shutdown action=reboot
osfirst=false
omconfig system thrmshutdown/omconfig servermodule thrmshutdown
Use the omconfig system thrmshutdown or omconfig servermodule
thrmshutdown command to configure a thermal shutdown action. A thermal
shutdown can be configured to occur when a temperature probe detects a
temperature probe warning or failure event.
Table 4-32 shows the valid parameters for the command.
Table 4-32. Thermal Shutdown Parameters
name=value
pair
Description
severity=
disabled |
warning |
failure
disabled: Disable thermal shutdown. An administrator must intervene.
warning: Perform a shutdown when a temperature warning event is
detected. A warning event occurs when any temperature probe inside a
chassis reads a temperature (in degrees Celsius) that exceeds the
maximum temperature warning threshold value.
failure: Perform a shutdown when a temperature failure event is
detected.
A failure event occurs when any temperature probe inside a chassis
reads a temperature (in degrees Celsius) that exceeds the maximum
temperature failure threshold value.
Comments to this Manuals