62 | Alarms
www.dell.com | support.dell.com
AC Supplies and Alarms
During system boot, if a redundant supply is removed or fails, the Dell Networking generates a minor
alarm message.
If only two supplies are installed and one of them fails, the software generates an alarm and an SNMP
trap (if configured), and lights the RPM alarm LED and supply LED.
Line Card Hardware failure major (red) major amber
Exceeds high temperature limit major (red) major unlit
Exceeds warning temperature limit minor (amber) minor green
Individual interface fails minor (amber) reported amber
RPM (Non-redundant Configuration with 1 RPM)
Exceeds high temperature limit major (red) major unlit
Exceeds warning temperature limit minor (amber) minor green
RPM fails but CP is ok major (red) major amber
Table A-1. Alarm Events and Reporting
Module Alarm Event Alarm LED Reported in
event log
Status LED on
Module