706 Traps
Voltage Probe Traps
Voltage probes monitor the number of volts across critical components.
Table 26-5. Voltage Probe Traps
Trap ID Description Severity Cause
Voltage Probe Normal
1152 Voltage sensor returned to
a normal value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete:
Voltage sensor value (in
Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>
Information A voltage sensor in the
specified system
returned to a valid range
after crossing a failure
threshold. The sensor
location, chassis
location, previous state,
and voltage sensor value
are provided.
Voltage Probe Warning
1153 Voltage sensor detected a
warning value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete:
Voltage sensor value (in
Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>
Warning A voltage sensor in the
specified system
exceeded its warning
threshold. The sensor
location, chassis
location, previous state,
and voltage sensor value
are provided.