Dell OpenManage Server Administrator Version 2.3 User's Guide Page 68

  • Download
  • Add to my manuals
  • Print
  • Page
    / 106
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 67
70 Storage Management Message Reference
2178 The controller battery
Learn cycle has
timed out.
Warning /
Non-critical
Cause: The controller battery must be fully
charged before the Learn cycle can begin.
The battery may be unable to maintain a full
charge causing the Learn cycle to timeout.
Additionally, the battery must be able to
maintain cached data for a specified period of
time in the event of a power loss. For
example, some batteries maintain cached
data for 24 hours. If the battery is unable to
maintain cached data for the required period
of time, then the Learn cycle will timeout.
Action: Replace the battery pack as the
battery is unable to maintain a full charge.
1153 None
2179 The controller battery
Learn cycle has been
postponed.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1151 None
2180 The controller battery
Learn cycle will start
in %1 days.
NOTE: The %1 is a
variable that will be
filled in with the
number of days before
which the Learn cycle
will start. You can set
the duration to start
the Learn cycle.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1151 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number
Page view 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 105 106

Comments to this Manuals

No comments