About Your System 41
Sector not found
Seek error
Seek operation
failed
Faulty hard drive, USB
device, or. USB medium.
See "Troubleshooting a USB
Device" on page 129,
"Troubleshooting an Internal
USB Key" on page 139, and
"Troubleshooting a Hard
Drive" on page 144.
Shutdown failure Shutdown test failure. See "Troubleshooting System
Memory" on page 137.
The amount of
system memory has
changed
Memory has been added
or removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module. See
"Troubleshooting a Hard
Drive" on page 144.
Time-of-day clock
stopped
Faulty battery or faulty
chip.
See "Troubleshooting the
System Battery" on page 134.
Time-of-day not set
- please run SETUP
program
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Entering the
System Setup Program" on
page 47. If the problem
persists, replace the system
battery. See "Troubleshooting
the System Battery" on
page 134.
Timer chip counter
2 failed
Faulty system board. See "Getting Help" on
page 167.
TPM configuration
operation honored
System will now restart. Information only.
Table 1-7. System Messages (continued)
Message Causes Corrective Actions