Dell T110 II Owner's Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 142
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
28 About Your System
The following
DIMMs should
match in
geometry:
x,x,...
Invalid memory
configuration. The
specified memory modules
do not match in size,
number of ranks, or
number of data lanes.
Ensure that the memory
modules are installed in a valid
configuration. See "General
Memory Module Installation
Guidelines" on page 86.
The following
DIMMs should
match in rank
count:
x,x,...
The following
DIMMs should
match in size:
x,x,...
The following
DIMMs should
match
in size
and geometry:
x,x,...
The following
DIMMs should
match
in size
and rank count:
x,x,...
Thermal sensor
not detected on
x.
A memory module without
a thermal sensor is installed
in the specified memory
slot.
Replace the memory module.
See "System Memory" on
page 86.
Time-of-day
clock stopped.
Faulty battery or faulty
chip.
See "Troubleshooting the
System Battery" on page 116.
Time-of-day not
set - please run
SETUP program.
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 35. If the problem
persists, replace the system
battery. See "System Battery"
on page 97.
Message Causes Corrective Actions
Coaster_HOM.book Page 28 Monday, November 3, 2014 3:23 PM
Page view 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 141 142

Comments to this Manuals

No comments