About Your System 21
PCIe Training
Error: Expected
Link Width is x,
Actual Link
Width is y.
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number. See
"Troubleshooting an
Expansion Card" on
page 109. If the problem
persists, see "Getting Help"
on page 119.
SATA Portx
device not
found.
There is no device connected
to the specified SATA port.
Information only.
SATA port x
device auto-
sensing error.
SATA port x
device
configuration
error.
SATA port x
device error.
The drive connected to the
specified SATA port is faulty.
Replace the faulty drive.
The amount of
system memory
has changed.
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module. See
"Troubleshooting System
Memory" on page 104.
Time-of-day not
set - please run
SETUP program.
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
System Setup Program and
Boot Manager" on page 25. If
the problem persists, replace
the system battery. See
"System Battery" on page 89.
Message Causes Corrective Actions