24
PCI Event Messages
PCI1300
Message A front panel diagnostic interrupt was detected.
Detailed
Description
The front panel diagnostic was pressed, and the system may be halted as a result. The
interrupt was user induced.
Recommended
Response Action
Reset the system to continue operation.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI1302
Message A bus time-out was detected on a component at bus
arg1
device
arg2
function
arg3
.
Arguments
arg1 =
bus
arg2 =
device
arg3 =
func
Detailed
Description
System performance may be degraded. The device has failed to respond to a transaction
(master/target abort or completion timeout).
Recommended
Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)