Using the Storage Management Service 183
omconfig Rescan Controller
Use the following omconfig command syntax to rescan a controller.
See Dell OpenManage Online Help for more information about Rescan
Controller.
Complete Syntax
omconfig storage controller action=rescan
controller=id
where id is the controller ID as reported by the omreport storage controller
command.
Example Syntax
To rescan controller 1, enter:
omconfig storage controller action=rescan
controller=1
NOTE: The rescan controller is not supported on non–RAID SCSI and SAS
controllers. Reboot the system for the configuration changes on non-RAID SCSI
controllers to be visible.
omconfig storage
controller
(continued)
action=setchangecontrollerproperties controller=<id>
abortcheckconsistencyonerror=<enabled/disabled>
allowreplacemember=<enabled/disabled> loadbalance=
<auto/disabled> autoreplacememberonpredictivefailure=
<enabled/disabled> /jointfilesconvert/71170/bgirate=<rate> reconstructrate=<rate>
rebuildrate=<rate> checkconsistencyrate=<rate>
clearredundantpath=disabled
action=discardpinnedcache controller=id force=e|d
omconfig storage
vdisk
action=replacememberdisk controller=id vdisk=id source=
<PDISKID> destination=<PDISKID>
Table 6-16. omconfig Controller Commands (continued)
Required Command
Levels (1, 2, 3)
Optional name=value pairs